Sony PEG-UX40 Troubleshooting Q&A - Page 18
The HotSync, An error message indicating insufficient memory appears
View all Sony PEG-UX40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
The HotSync® operation does not start and a message appears on the screen B If you set the IR port to search automatically for the target IR devices on your computer, follow the procedure below to reset the IR port setting. 1 Click [Start], select [Settings] (except for Windows XP), and click [Control Panel]. 2 Double-click the Infrared icon (the Wireless Link icon in Windows 2000 Professional/Windows XP). 3 Click [Sending image]. 4 Deselect [Send the image from the digital camera to your computer using the wireless link] and click [OK]. 5 Click (HotSync) in the task tray at the bottom right of your computer window and select [InfraRed] from the shortcut menu. An error message indicating insufficient memory appears while receiving data using the IR port or the Bluetooth® communication B To receive data using the IR port or the Bluetooth® communication, the free space of your CLIÉ handheld's memory must be more than twice the size of data to be received. If there is insufficient memory space in your CLIÉ handheld, delete any unnecessary data (after backing up any of that data you might need in the future) and try receiving data again. B Perform a soft reset by pressing the RESET button. b For details, refer to "Basic operations of your CLIÉ™ handheld: Restarting your CLIÉ™ handheld" in the supplied "Read This First (Operating Instructions)". 18