System Board Troubleshooting, Troubleshooting Procedures, Table 2-4-2, Debug port Boot mode error
View all Toshiba Tecra A8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
2.4 System Board Troubleshooting 2 Troubleshooting Procedures Table 2-4-2 Debug port (Boot mode) error status (6/9) D port status Inspection items Details F109 Task generation for waiting INIT_PCI completion Initialization of SVP (model supporting SVP) CMOS data initialization (2) PnP initialization F10A Setting of setup items Waiting for the completion of Multibox status check H/W setting based on resource Task generation for waiting PnP resource making completion PnP H/W initialization PC card slot initialization SIO initialization (for models supporting SIO) FIR initialization (for models supporting FIR) PCI automatic configuration Making of work for automatic configuration Acquisition of PCI IRQ Configuration Saving the result of VGA configuration F10B Task generation for waiting PCI_CONFIGURATION completion Initialization of H/W necessary after Printer port setting (for models supporting printer) PCI configuration HDD initialization sequence start FDD initialization sequence start (for models supporting printer internal FDD) Enabling power off Output code generation F10C FIRST_64KB_CHECK (Check of first 64KB memory) F10D INIT_INT_VECTOR (Initialization of vectors) F10E INIT_NDP (Initialization of NDP) F10F INIT_SYSTEM (Initialization of system) Storing of CMOS error status to IRT_ERR_STS_BUF TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573) [CONFIDENTIAL] 2-39