Viking VIPR161SS Installation Instructions - Page 3

Plan The Ductwork, Take Measurements - downdraft

Page 3 highlights

VIKING RANGE CORPORATION TAKE MEASUREMENTS (CONTINUED) Downdraft Ventilators Interior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER 2" 7 11 16 " 1" 3 1 4 " 3 5 8 " 18" 5" VVIIDV550000 ININTTEERRNIOARL BBLLOOWWEERR 1" 4 2 1 8 " 29 5 16 " FROM COUNTERTOP TO BOTTOM OF AIR BOX Exterior Blower Installation SIDE VIEW OF DOWNDRAFT WITH 10" ROUND ELBOW (for connection to VEDV900 or VEDV1200 Exterior Blower) 7 11 " 16 3 1 4 1" " 3 5 8 " 3 3 16 " 13 1 4 " 10" ROUND ELBOW 2" 1" 4 2 1 8 " 29 5 16 " FROM COUNTERTOP TO BOTTOM OF AIR BOX PLAN THE DUCTWORK Interior Blower Installation 1. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are available with side-toside adjustment for accurate alignment of ductwork. LEFT DISCHARGE 2. For best performance: RIGHT Choose the ducting DISCHARGE option which allows the shortest length of ductwork and a DOWN DISCHARGE minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. 6" ROUND ELBOW 3-1/4" X 10" TO 6" RD. TRANSITION 3-1/4" X 10" 90O ELBOW 1 9 16 " 13 1 4 " Exterior Blower Installation 1. The exterior downdraft blower system is designed for use with 10" round ductwork. 2. For best performance: Plan ducting which has the shortest length of ductwork and a minimum number of elbows. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. 10" ROUND DISCHARGE PLATE 10" ROUND ELBOW EQUALS 6 FT. OF STRAIGHT DUCT EQUALS 6 FT. OF STRAIGHT DUCT EQUALS 2 FT. OF STRAIGHT DUCT EQUALS 8 FT. OF STRAIGHT DUCT 3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less. 3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The illustration, above, shows equivalent feet of a 10" round elbow.The number of feet of straight duct plus the equivalent feet of elbows to be used should equal 40 feet or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

3
VIKING RANGE CORPORATION
Downdraft Ventilators
1. The interior
down-
draft blower system is
designed for use with
3-1/4" x 10" ductwork
(can be transitioned
to 6" round). Three
different discharge
directions are avail-
able with side-to-
side adjustment for
accurate alignment of
ductwork.
2. For best performance:
Choose the ducting
option which allows
the shortest length
of ductwork and a
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
PLAN THE DUCTWORK
Interior Blower Installation
Exterior Blower Installation
10" ROUND
DISCHARGE
PLATE
1. The exterior downdraft
blower system is designed
for use with 10" round duct-
work.
2. For best performance:
Plan ducting which has the
shortest length of ductwork
and a minimum number of
elbows. Check location of
floor joists, wall studs, elec-
trical wiring or plumbing for
possible interference.
EQUALS 6 FT. OF
STRAIGHT DUCT
10" ROUND
ELBOW
EQUALS 6 FT. OF
STRAIGHT DUCT
6" ROUND
ELBOW
EQUALS 8 FT. OF
STRAIGHT DUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
3-1/4" X 10" TO 6" RD.
TRANSITION
3-1/4" X 10"
90
O
ELBOW
29
"
5
16
2
"
1
8
5"
2"
1"
3
"
1
4
3
"
5
8
1
4
7
"
11
16
18"
FROM
COUNTERTOP
TO BOTTOM
OF AIR BOX
"
29
"
5
16
2
"
1
8
2"
1"
3
"
1
4
3
"
5
8
1
4
7
"
11
16
FROM
COUNTERTOP
TO BOTTOM
OF AIR BOX
"
3
"
3
16
1
4
"
13
1
4
"
13
1
"
9
16
10" ROUND
ELBOW
minimum number of elbows and transitions. Check location
of floor joists, wall studs, electrical wiring or plumbing for
possible interference.
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The illustration,
above, shows equivalent feet of a 10" round elbow.The number
of feet of straight duct plus the equivalent feet of elbows to be
used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
Interior Blower Installation
Exterior Blower Installation
TAKE MEASUREMENTS
(CONTINUED)
EQUALS
2 FT. OF
STRAIGHT DUCT
SIDE VIEW
OF DOWNDRAFT
WITH
VIDV500
INTERIOR
BLOWER
SIDE VIEW
OF DOWNDRAFT
WITH
10" ROUND ELBOW
(for connection
to VEDV900 or
VEDV1200 Exterior
Blower)
VIDV500
INTERIOR
BLOWER