Yamaha DTXPRESS Reference Guide - Page 13

Velocity Curve, Specific Rejection, Self Rejection, Rejection, Trigger Setup Copy

Page 13 highlights

1-3. Velocity Curve This function sets the MIDI Velocity Curve for the sensitivity for each input jack q. TRIG IN= 1 q VelCurve= normal w q TRIG IN (Trigger Input Number) Assigns the trigger input jack number (the same procedure as in [1-1. Pad Type]). w VelCurve (Velocity Curve) Sets the Input Velocity Curve for the trigger input jack assigned in TRIG IN q. normal loud 2 loud1 hard 1 hard 2 m Velocity Strength of hitm 1-4. Self Rejection, Rejection This function is used to prevent double triggers* and cross talk (mixed input signals between the jacks) for each input jack q. * double trigger: When 2 sounds are played at the same time. TRIG IN= 1 q SelfRej=2 Rej= 3 w e q TRIG IN (Trigger Input Number) Assigns the trigger input jack number (the same procedure as in [1-1. Pad Type]). w SelfRej (Self Rejection) [Range] 0-9 Prevents double triggers from occuring in the input jack assigned in TRIG IN q. After an event is detected, further events will be automatically muted for a certain length of time. Larger values set longer times. e Rej (Rejection) [Range] 0-9 Prevents cross talk from occuring in the input jack assigned in TRIG IN q. Events triggered by other pads (input jacks) that are of a lower input value than what is set here will not be delivered for a set length of time. Trigger Setup Edit Mode 1-5. Specific Rejection This function prevents cross talk from occurring between two specified input jacks q and e. TRIG IN= 1 q SPCRej=0 frm= 1 w e q TRIG IN (Trigger Input Number) Assigns the trigger input jack number (the same procedure as in [1-1. Pad Type]). w SPCRej (Specific Rejection) [Range] 0-9 After an event occurs from the pad from the input jack assigned in e, the pad of the input jack assigned in TRIG IN q will not sound for a certain length of time unless the level is greater than the value assigned here. e frm (Assigned Destination Trigger Input Number) [Range] 1-10, 6&7 Sets the destination trigger input jack number of the pad that will be rejected. When "6&7" is selected, both trigger inputs 6 and 7 will be assigned. 1-6. Trigger Setup Copy This function copies all data settings in [1-1. Pad Type] to [1-5. Specific Rejection] from input jack q to another input jack w. TRIG IN= 1 q Copy to Input= 1 w When the Trigger Setup Copy operation is carried out, the trigger setup data will be replaced with the settings of the copy source. q TRIG IN (Trigger Input Number) Sets the trigger input jack number (1-10) of the pad copy source. w Copy to Input (Trigger Input Number Copy Destination) Sets the trigger input jack number (1-10) of the copy destination. Procedure 1. In the display shown above, assign the copy source and copy destination, press the [SAVE/ENT] button. The following display will appear asking for confirmation before the copy operation is carried out. Input Copy to 1 Are you sure ? 2. Press the [SAVE/ENT] or [VALUE+] button, the copy operation will be carried out. * Press the [VALUE-] button to cancel the copy operation. When the copy operation is complete, "Complete!" will appear. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

13
1-3.
Velocity Curve
This function sets the MIDI Velocity Curve for the sensitivity for
each input jack
q
.
1-5.
Specific Rejection
This function prevents cross talk from occurring between two speci-
fied input jacks
q
and
e
.
q
TRIG IN (Trigger Input Number)
Assigns the trigger input jack number (the same procedure as in
[1-1. Pad Type]).
w
VelCurve (Velocity Curve)
Sets the Input Velocity Curve for the trigger input jack assigned in
TRIG IN
q
.
1-4.
Self Rejection, Rejection
This function is used to prevent double triggers
*
and cross talk
(mixed input signals between the jacks) for each input jack
q
.
*
double trigger:
When 2 sounds are played at the same time.
q
TRIG IN (Trigger Input Number)
Assigns the trigger input jack number (the same procedure as in
[1-1. Pad Type]).
w
SelfRej (Self Rejection)
[Range]
0-9
Prevents double triggers from occuring in the input jack assigned
in TRIG IN
q
. After an event is detected, further events will be
automatically muted for a certain length of time. Larger values set
longer times.
e
Rej (Rejection)
[Range]
0-9
Prevents cross talk from occuring in the input jack assigned in
TRIG IN
q
. Events triggered by other pads (input jacks) that are
of a lower input value than what is set here will not be delivered
for a set length of time.
q
TRIG IN (Trigger Input Number)
Assigns the trigger input jack number (the same procedure as in
[1-1. Pad Type]).
w
SPCRej (Specific Rejection)
[Range]
0-9
After an event occurs from the pad from the input jack assigned in
e
, the pad of the input jack assigned in TRIG IN
q
will not
sound for a certain length of time unless the level is greater than
the value assigned here.
e
frm (Assigned Destination Trigger Input Number)
[Range]
1-10, 6&7
Sets the destination trigger input jack number of the pad that will
be rejected. When “
6&7
” is selected, both trigger inputs 6 and 7
will be assigned.
1-6.
Trigger Setup Copy
This function copies all data settings in [1-1. Pad Type] to [1-5.
Specific Rejection] from input jack
q
to another input jack
w
.
When the Trigger Setup Copy operation is carried
out, the trigger setup data will be replaced with the
settings of the copy source.
q
TRIG IN (Trigger Input Number)
Sets the trigger input jack number (1-10) of the pad copy source.
w
Copy to Input (
Trigger Input Number Copy Destination
)
Sets the trigger input jack number (1-10) of the copy destination.
Pr
ocedure
1.
In the display shown above, assign the copy source and
copy destination, press the [SAVE/ENT] button. The fol-
lowing display will appear asking for confirmation before
the copy operation is carried out.
TRIG
°
IN=
°
1
VelCurve=
°
normal
w
q
TRIG
°
IN=
°
1
SelfRej=2
°
Rej=
°
3
w
e
q
TRIG
°
IN=
°
1
SPCRej=0
°
frm=
°°
1
q
e
TRIG
°
IN=
°
1
Copy
°
to
°
Input=
°
1
w
q
Trigger Setup Edit Mode
normal
hard
°
2
hard
°
1
loud1
loud
°
2
Input
°
Copy
°
to
°
1
°
Are
°
you
°
sure
°
?
2.
Press the [SAVE/ENT] or [VALUE+] button, the copy
operation will be carried out.
* Press the [VALUE-] button to cancel the copy operation.
When the copy operation is complete, “
Complete!
” will appear.
w
Strength
of hit
m
V
elocity
m