Yamaha MOXF8 Reference Manual - Page 88
Modify Velocity, Modify Gate Time, GateTime, TR Track 001 : 1 : 000 - 999 : 4 : 479, SetAll, Offset
View all Yamaha MOXF8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
VOICE PERF SONG PATTERN MIX MASTER REMOTE UTILITY QUICK SET FILE GateTime Determines the gate time (the length of time a note sounds) of the even-numbered backbeat notes to enhance the swing feel. When a triplet quantize value is used, the gate time of the last note of each triplet is adjusted. When the quantize value is 8th note + 8th note triplet or 16th note + 16th note triplet, the gate time of the even-numbered 8th note or 16th note beats will be adjusted. A setting of 100% leaves the original gate time unchanged. If an adjusted gate time value is less than 1, the value is rounded off to 1. Settings: 000% - 200% 02: Modify Velocity This Job alters the velocity values of the specified range of notes, letting you selectively boost or cut the volume of those notes. Velocity changes are calculated as follows: Adjusted velocity = (original velocity x Rate) + Offset If the result is 0 or less, the value is set to 1. If the result is higher than 127, the value is set to 127. TR (Track) 001 : 1 : 000 - 999 : 4 : 479 Determines the Track (01 - 16, all) and range of measures/beats/clocks over which the Job is applied. SetAll Sets the velocities of all target notes to the same fixed value (1 to 127). When set to "OFF" the Set All parameter has no effect. When this is set to a value other than "off," the Rate and Offset parameters are unavailable and appear as "***" on the display. Settings: off (0), 001 - 127 Rate Determines the percentage by which the target notes will be shifted from their original velocities. Settings below 100% reduce the velocities, and settings above 100% increase the velocities proportionately. A setting of 100 produces no change. When the Set All parameter is not set to "off," this parameter appears as "***" and cannot be changed. Settings: 000% - 200%, *** Offset Adds a fixed value to the Rate-adjusted velocity values. Settings below 0 reduce the velocities, and settings above 0 increase the velocities. A setting of 0 produces no change. When the Set All parameter is not set to "off," this parameter appears as "***" and cannot be changed. Settings: -127 - +0 - +127, *** 03: Modify Gate Time This Job alters the gate times of the specified range of notes. Gate time changes are calculated as follows: Adjusted gate time = (original gate time x Rate) + Offset If the result is 0 or less, the value is rounded off to 1. TR (Track) 001 : 1 : 000 - 999 : 4 : 479 Determines the Track (01 - 16, all) and range of measures/beats/clocks over which the Job is applied. SetAll Sets the gate times of all target notes to the same fixed value. When set to "OFF," the Set All parameter has no effect. When set to a value other than "off," the Rate and Offset parameters are unavailable and appear as "***" on the display. Settings: off (0), 0001 - 9999 Song Mode Song Play [F1] PLAY [F2] GROOVE [F3] TRACK [F6] CHAIN Song Record Song Record Standby [F1] SETUP [F2] VOICE [F3] ARP ED [F5] CLICK [F6] ALL TR During Song Recording [F1] SETUP [F3] REST [F4] TIE [F5] DELETE [F6] BAK DEL Arpeggio Edit [F1] COMMON [F2] TYPE [F3] MAIN [F4] LIMIT [F5] PLAY FX [F6] OUT CH Song Edit [F1] CHANGE [F2] VIEW FLT [F4] TR SEL [F5] INSERT [F6] DELETE Song Job [F1] UNDO/REDO [F2] NOTE [F3] EVENT [F4] MEAS [F5] TRACK [F6] SONG Supplementary Information Rate Determines the percentage by which the gate time of the target notes will be changed. Settings below 100% shorten the notes, and settings above 100% lengthen the notes proportionately. A setting of 100 produces no change. When the Set All parameter is not set to "off," this parameter appears as "***" and cannot be changed. Settings: 000% - 200%, *** Offset Adds a fixed value to the Rate-adjusted gate time values. Settings below 0 shorten the gate time, and settings above 0 lengthen the gate time. A setting of 0 produces no change. When the Set All parameter is not set to "off," this parameter appears as "***" and cannot be changed. Settings: -9999 - +0 - +9999, *** MOXF6/MOXF8 Reference Manual 88