Chapter 34 Access Control 34.3.3 SNMP Traps The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the SNMP traps by category. An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.8" is defined in private MIBs. Otherwise, it is a standard MIB OID. Table 103 SNMP System Traps OPTION coldstart OBJECT LABEL coldStart warmstart warmStart fanspeed FanSpeedEventOn FanSpeedEventClear temperature TemperatureEventOn TemperatureEventClear OBJECT ID DESCRIPTION 1.3.6.1.6.3.1.1.5.1 This trap is sent when the Switch is turned on. 1.3.6.1.6.3.1.1.5.2 This trap is sent when the Switch restarts. MGS-3712F: This trap is sent when the fan 1.3.6.1.4.1.890.1.5.8.48.2 speed goes above or below the 5.2.1 normal operating range. MGS-3712: 1.3.6.1.4.1.890.1.5.8.47.2 5.2.1 MGS-3712F: This trap is sent when the fan 1.3.6.1.4.1.890.1.5.8.48.2 speed returns to the normal 5.2.2 operating range. MGS-3712: 1.3.6.1.4.1.890.1.5.8.47.2 5.2.2 MGS-3712F: 1.3.6.1.4.1.890.1.5.8.48.2 5.2.1 MGS-3712: 1.3.6.1.4.1.890.1.5.8.47.2 5.2.1 This trap is sent when the temperature goes above or below the normal operating range. MGS-3712F: This trap is sent when the 1.3.6.1.4.1.890.1.5.8.48.2 temperature returns to the 5.2.2 normal operating range. MGS-3712: 1.3.6.1.4.1.890.1.5.8.47.2 5.2.2 308 MGS-3712/MGS-3712F User's Guide