3Com 3812 Getting Started Guide - Page 63

Technical Specifications, Switch 3812, and Switch 3848, T

Page 63 highlights

C TECHNICAL SPECIFICATIONS Switch 3812, Switch 3824, and Switch 3848 Physical Dimensions Switch 3812 and Switch 3824 Height: 43.6 mm (1.72 in) x Width: 440 mm (17.3 in.) x Depth: 325 mm (12.8 in.). Weight: 3.7 kg (8.2 lb) (Switch 3812), 4.0 kg (8.8 lb) (Switch 3824). Switch 3848 Height: 43.6 mm (1.72 in) x Width: 440 mm (17.3 in.) x Depth: 415 mm (16.3 in.). Weight: 5.0 kg (11.0 lbs). Environmental Requirements Operating Temperature 0 ° to 40 °C (32 ° to 104 °F) Storage Temperature -10 ° to +70 °C (14 ° to 158 °F) Operating Humidity 10-95% relative humidity, non-condensing Standards EN60068 to 3Com schedule (package testing: paras 2.1, 2.2, 2.30 and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13. Safety Agency Certifications UL 60950, EN60950, CSA 22.2 No. 60950, IEC 60950, IEC825-1, EN60825-1 EMC Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3 Immunity EN 55024 Power Consumption Switch 3812 53 W maximum Switch 3824 82 W maximum Switch 3848 150 W maximum Heat Dissipation Switch 3812 181 BTU/hour maximum Switch 3824 280 BTU/hour maximum Switch 3848 511 BTU/hour maximum Power Supply AC Line Frequency 50/60 Hz

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

C
T
ECHNICAL
S
PECIFICATIONS
Switch 3812, Switch 3824, and Switch 3848
Physical Dimensions
Switch 3812 and Switch 3824
Height: 43.6 mm (1.72 in) x Width: 440 mm (17.3 in.) x Depth: 325 mm (12.8 in.).
Weight: 3.7 kg (8.2 lb) (Switch 3812), 4.0 kg (8.8 lb) (Switch 3824).
Switch 3848
Height: 43.6 mm (1.72 in) x Width: 440 mm (17.3 in.) x Depth: 415 mm (16.3 in.).
Weight: 5.0 kg (11.0 lbs).
Environmental Requirements
Operating Temperature
0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature
–10 ° to +70 °C (14 ° to 158 °F)
Operating Humidity
10–95% relative humidity, non-condensing
Standards
EN60068 to 3Com schedule (package testing: paras 2.1, 2.2, 2.30 and 2.32.
Operational testing: paras 2.1, 2.2, 2.30 and 2.13.
Safety
Agency Certifications
UL 60950, EN60950, CSA 22.2 No. 60950, IEC 60950, IEC825-1, EN60825-1
EMC
Emissions
CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3
Immunity
EN 55024
Power Consumption
Switch 3812
53 W maximum
Switch 3824
82 W maximum
Switch 3848
150 W maximum
Heat Dissipation
Switch 3812
181 BTU/hour maximum
Switch 3824
280 BTU/hour maximum
Switch 3848
511 BTU/hour maximum
Power Supply
AC Line Frequency
50/60 Hz