3Ware 3W-6800 User Guide - Page 165
AEN 028h AEN_DCB_BAD_VERSION, AEN 029h AEN_VERIFY_STARTED, RAID 10. Verify = Compare of Mirror Sides
View all 3Ware 3W-6800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 165 highlights
Troubleshooting performs a checksum of the DCB area to ensure consistency. If an error occurs, please contact 3ware technical support. The drive's DCB has been corrupted. AEN 028h AEN_DCB_BAD_VERSION During the evolution of the Escalade product line, the format of the DCB has been changed to accommodate new features. The DCB format expected by the storage switch and the DCB that is written on the drive must be compatible. If an array that was created on a very old Escalade product is connected to a newer Escalade storage switch, this AEN is posted and the storage switch rejects the drive. Please contact 3ware technical support if this event occurs. AEN 029h AEN_VERIFY_STARTED The storage switch allows the user to verify data integrity on an array.The verification functions for different RAID levels are as follows: • JBOD. Verify = Media Scan • RAID 0. Verify = Media Scan • RAID 1. Verify = Compare of Mirror Sides • RAID 10. Verify = Compare of Mirror Sides • RAID 5. Verify = Parity Data = User Data When the verification starts, this AEN is posted to the user. AEN 02Ah AEN_VERIFY_FAILED This AEN indicates that the data integrity verification function (see AEN 029h) has terminated with an error. For each RAID level being verified, this may mean: • JBOD. A single drive returned an error, possibly because of a media defect. • RAID 0. A single drive returned an error, possibly because of a media defect. • RAID 1. One side of the mirror does not equal the other side. www.3ware.com 155