Asus ROG CROSSHAIR X670E EXTREME ROG CROSSHAIR X670E Series BIOS manual Englis - Page 86

Water Pump+ Point4 Duty Cycle

Page 86 highlights

The following items appear only when Water Pump+ Profile is set to [Manual]. Water Pump+ Point4 Temperature When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the Point4 temperature. Water Pump+ Point4 Duty Cycle (%) When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the Point4 temperature. Water Pump+ Point3 Temperature When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. Water Pump+ Point3 Duty Cycle (%) When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. Water Pump+ Point2 Temperature When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P1-P2 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. Water Pump+ Point2 Duty Cycle (%) When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P1-P2 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. Water Pump+ Point1 Temperature When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. Water Pump+ Point1 Duty Cycle (%) When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. 86 ROG CROSSHAIR X670E Series BIOS Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

86
ROG CROSSHAIR X670E Series BIOS Manual
The following items appear only when
Water Pump+ Profile
is set to
[Manual].
Water Pump+ Point4 Temperature
When the temperature source is lower than the temperature of P4, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P4, the fan will operate at the
duty cycle of P4. Use the <+> or <-> keys to adjust the Point4 temperature.
Water Pump+ Point4 Duty Cycle (%)
When the temperature source is lower than the temperature of P4, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P4, the fan will operate at the
duty cycle of P4. Use the <+> or <-> keys to adjust the Point4 temperature.
Water Pump+ Point3 Temperature
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. Use the <+> or <->
keys to adjust the Point3 temperature.
Water Pump+ Point3 Duty Cycle (%)
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. Use the <+> or <->
keys to adjust the Point3 temperature.
Water Pump+ Point2 Temperature
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. Use the <+> or <->
keys to adjust the Point2 temperature.
Water Pump+ Point2 Duty Cycle (%)
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. Use the <+> or <->
keys to adjust the Point2 temperature.
Water Pump+ Point1 Temperature
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to the P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the Point1 temperature.
Water Pump+ Point1 Duty Cycle (%)
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to the P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the Point1 temperature.