WSW06, Pause, Detection of international tone
View all Brother International 8250P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
WSW06 (Pause key setting and 2nd dial tone detection) Selector No. Function 1 | Pause key setting and 2nd dial tone detection 3 4 | Detection of international tone 6 7 No. of 2nd dial tone detection times 8 2nd dial tone interrupt detecting time Setting and Specifications No. 1 2 3 000: 001: 010: 011: 100: 110: 101: 111: No pause 3.5 sec. WAIT 7 sec. WAIT 10.5 sec. WAIT 14 sec. WAIT 2nd dial tone detection only in pulse dialing (DP) system 2nd dial tone detection both in DP and push-button (PB) dialing system No. 4 5 6 000: 001: 010: 011: 100: 101: 110: 111: 50 ms 210 ms 500 ms 800 ms 900 ms 1.5 sec. 2.0 sec. 2.5 sec. 0: Once 1: Twice 0: 30 ms 1: 50 ms NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is supported, e.g., U.S.A. V - 18