to 5 times
View all Brother International 8250P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
WSW14 (AUTO ANS facility setting) Selector No. Function 1 Frequency band selection 2 (Lower limit) 3 Frequency band selection 4 (Upper limit) 5 | No. of rings in AUTO ANS mode 8 Setting and Specifications No. 1 2 00: 01: 10: 11: 13 Hz 15 Hz 23 Hz 20 Hz No. 3 4 00: 01: 1 X: 30 Hz 55 Hz 70 Hz No. 5 6 7 8 0000 : 0001 : 0010 : 0011 : 0100 : 0101 : 0110 : 0111 : 1000 : 1001 : 1010 : 1011 : 1100 : 1101 : 1110 : 1111 : Fixed to once Fixed to 2 times Fixed to 3 times Fixed to 4 times 1 to 2 times 1 to 3 times 1 to 4 times 1 to 5 times 2 to 3 times 2 to 4 times 2 to 5 times 2 to 6 times 1 to 10 times 2 to 10 times 3 to 5 times 4 to 10 times l Selectors 1 through 4: Frequency band selection These selectors are used to select the frequency band of calling signals for activating the AUTO ANS facility. In the French versions, if the user sets the PBX to OFF from the control panel, the setting made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if the setting made by these selectors does not apply, it will be printed on the configuration list.) l Selectors 5 through 8: No. of rings in AUTO ANS mode These selectors set the number of rings to initiate the AUTO ANS facility. V - 27