Brother International 8250P Service Manual - Page 133

TEL/POLLING key, This setting is effective only for those models having a programmable key.

Page 133 highlights

Selector No. 1 2 3 4 5 6 7 8 WSW27 (Function setting 5) Function Definition of programmable key Ringer OFF setting Automatic playback of OGM at the start time of OGM ON mode Detection of distinctive ringing pattern Not used. Recording quality level Sampling rate when the recording quality level is set to High Toner save mode Setting and Specifications 0: TEL key 1: TEL/POLLING key 0: Yes 1: No 0: No 1: Yes 0: Yes 1: No 0: Normal 1: High 0: Short 1: Long 0: Yes 1: No NOTE: Selector 1 is not applicable to the U.S.A. versions. NOTE: Selectors 3, 6 and 7 are applicable to those models equipped with a built-in TAD. l Selector 1: Definition of programmable key This selector defines a programmable key as a TEL key or TEL/POLLING key. Setting this selector to "1" allows the programmable key to function as either a TEL or POLLING key if pressed when the handset is off or on the hook, respectively. This setting is effective only for those models having a programmable key. l Selector 2: Ringer OFF setting This selector determines whether or not the ringer can be set to OFF. l Selector 3: Automatic playback of OGM at the start time of OGM ON mode This selector determines whether or not the equipment automatically plays back an OGM the moment it switches to the OGM ON mode in the MC mode. l Selector 4: Detection of distinctive ringing pattern If this selector is set to "1" the equipment detects only the number of rings; if it is set to "0" the equipment detects the number of rings and the ringing time length to compare the detected ringing pattern with the registered distinctive one. l Selector 6: Recording quality level This selector determines the recording quality level (this function can be accessed also by the user function 8-8). If it is set to "0" (Normal), the sampling rate specified by selector 4 of WSW30 takes effect; if it is set to "1" (High), the sampling rate by selector 7 of WSW27 takes effect. l Selector 7: Sampling rate when the recording quality level is set to Normal This selector determines the sampling rate when selector 6 of WSW27 is set to "1" (High). If this selector is set to "0," the sampling rate is 9.6 kbps; if it is set to "1," the sampling rate is 8.8 kbps. V - 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

V
- 40
WSW27
(Function setting 5)
Selector
No.
Function
Setting and Specifications
1
Definition of programmable key
0:
TEL key
1:
TEL/POLLING key
2
Ringer OFF setting
0:
Yes
1:
No
3
Automatic playback of OGM at the
start time of OGM ON mode
0:
No
1:
Yes
4
Detection of distinctive ringing
pattern
0:
Yes
1:
No
5
Not used.
6
Recording quality level
0:
Normal
1:
High
7
Sampling rate when the recording
quality level is set to High
0:
Short
1:
Long
8
Toner save mode
0:
Yes
1:
No
NOTE:
Selector 1 is not applicable to the U.S.A. versions.
NOTE:
Selectors 3, 6 and 7 are applicable to those models equipped with a built-in TAD.
l
Selector 1:
Definition of programmable key
This selector defines a programmable key as a TEL key or TEL/POLLING key.
Setting this selector to "1" allows the programmable key to function as either a TEL or POLLING
key if pressed when the handset is off or on the hook, respectively.
This setting is effective only for those models having a programmable key.
l
Selector 2:
Ringer OFF setting
This selector determines whether or not the ringer can be set to OFF.
l
Selector 3:
Automatic playback of OGM at the start time of OGM ON mode
This selector determines whether or not the equipment automatically plays back an OGM the
moment it switches to the OGM ON mode in the MC mode.
l
Selector 4:
Detection of distinctive ringing pattern
If this selector is set to "1" the equipment detects only the number of rings; if it is set to "0" the
equipment detects the number of rings and the ringing time length to compare the detected ringing
pattern with the registered distinctive one.
l
Selector 6:
Recording quality level
This selector determines the recording quality level (this function can be accessed also by the user
function 8-8).
If it is set to "0" (Normal), the sampling rate specified by selector 4 of WSW30
takes effect; if it is set to "1" (High), the sampling rate by selector 7 of WSW27 takes effect.
l
Selector 7:
Sampling rate when the recording quality level is set to Normal
This selector determines the sampling rate when selector 6 of WSW27 is set to "1" (High).
If this