Brother International 8250P Service Manual - Page 71
CAUTION, Reassembling Notes, If you have touched it, clean it thoroughly
View all Brother International 8250P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
(6) To take out the FU lamp from the heat-fixing unit, remove two screws "b." (7) Unhook the two latches outwards with the tip of a small flat screwdriver and open the upper cover. (8) Fully open the upper cover and remove it. (9) Remove screw "d" and loosen screw "c." (10) Hold the lock plate of the FU lamp between your fingers and pull out the FU lamp from the heater roller. CAUTION: Do not touch the FU lamp. If you have touched it, clean it thoroughly with alcohol. n Reassembling Notes • When setting the FU lamp into the heat-fixing unit, be sure to insert the right edge of the wire into the folded lock plate. • A new heat-fixing unit will be provided with the heater thermister harness being taped to the unit. When installing the unit, remove the tape. IV - 27