Brother International 8250P Service Manual - Page 141
Detection time length of the, disconnection tone in ICM
![]() |
View all Brother International 8250P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Selector No. 1 | 4 5 | 8 WSW35 (Function setting 13) Function Detection time length of the disconnection tone in ICM recording Setting and Specifications No. 1 0 0 0 0 1 234 000: 001: 010: 100: | 111: No detection 1 sec. 2 sec. 4 sec. | 15 sec. Not used. NOTE: Selectors 1 through 4 are applicable to those models equipped with a built-in TAD. l Selectors 1 through 4: Detection time length of the disconnection tone in ICM recording If the equipment detects disconnection tone for the time length set by these selectors, it will disconnect the line. V - 48
![](/manual_guide/products/brother-international-mfc-9050-service-manual-c68f5f0/141.png)
V
- 48
WSW35
(Function setting 13)
Selector
No.
Function
Setting and Specifications
1
|
4
Detection time length of the
disconnection tone in ICM
recording
No. 1
2
3
4
0
0
0
0
:
No detection
0
0
0
1
:
1 sec.
0
0
1
0
:
2 sec.
0
1
0
0
:
4 sec.
|
|
1
1
1
1
:
15 sec.
5
|
8
Not used.
NOTE:
Selectors 1 through 4 are applicable to those models equipped with a built-in TAD.
l
Selectors 1 through 4:
Detection time length of the disconnection tone in ICM recording
If the equipment detects disconnection tone for the time length set by these selectors, it will
disconnect the line.