Brother International HL-1070 Service Manual - Page 191
Table 1: Serial Interface Parameter Settings, Table 2: Baud Rate Settings
![]() |
View all Brother International HL-1070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 191 highlights
CHAPTER 4 OPTIONS If necessary, set the serial interface parameters as follows: 1. Make sure that the printer is in the off-line state. 2. Set the serial interface parameters by moving up (on) or down (off) the selectors of the dual in-line package (DIP) switch. ON 12 345678 Fig. 4-2 Setting the Serial Interface Parameters Table 1: Serial Interface Parameter Settings Selector 1 2 3 4 5 6 7 8 Parameters Baud Rate Baud Rate Data Length Stop Bit Parity Parity Protocol Robust Xon On (up) Off (down) - See Table 2. - - See Table 2. - 7 bits 8 bits 2 bits 1 bit - See Table 3. - - See Table 3. - Xon/Xoff + DTR DTR only On Off Table 2: Baud Rate Settings Selector 1 Off On Off On Selector 2 Off Off On On For RS-422A 57600 9600 1200 19200 For RS-232C 9600 4800 1200 19200 4-3