Brother International HL-1070 Service Manual - Page 57
Fig. 3.28, Low-voltage Power Supply PCB ASSY, Note 1: When reassembling
View all Brother International HL-1070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
(2) Disconnect the eleven connectors from the PCB. (Three connectors have already been disconnected when removing the scanner unit.) 5 1 Driver PCB ASSY 2 7 4 3 8 9 10 11 12 13 Main frame Fig. 3.28 (Name of the harnesses) 1. SW panel harness 2. Scan motor harness 3. Toner harness 4. Laser harness 5. Fan motor harness 7. Main connector 8. High-voltage flat cable 9. Erase lamp harness 10. SR harness 11. Solenoid harness 12. Main motor harness 13. Low-voltage harness Note 1: When reassembling, the cable connectors must be inserted securely into the PCB connectors and the PCB must not be stressed by the harnesses. Note 2: The connectors should be inserted by matching the housing color and the number of pins. 3.13 Low-voltage Power Supply PCB ASSY (1) Remove the screw securing the low-voltage power supply PCB ASSY. (2) Disconnect the two connectors for the heater harness and the LV harness from the PCB. Screw LV harness Low-voltage power supply ASSY H r h rn Fig. 3.29 Main cover III-17