Brother International HL 1240 Users Manual - English - Page 48

Table 1: Serial Interface Parameters Settings, Table 2: Baud Rate Settings

Page 48 highlights

Table 1: Serial Interface Parameters Settings Selector 1 2 3 4 5 6 7 8 Parameters Baud Rate Baud Rate Data Length Stop Bit Parity Parity Protocol Robust Xon On (up) See Table 2 See Table 2 7 bits 2 bits See Table 3. See Table 3. Xon/Xoff + DTR On Off (down) 8 bits 1 bit DTR only Off Table 2: Baud Rate Settings Selector 1 Off On Off On Selector 2 Off Off On On For RS-422A 57600 9600 1200 19200 For RS-232C 9600 4800 1200 19200 Table 3: Parity Settings Selector 5 On On Off Selector 6 On Off Off Parity Odd Even None  Note • The factory settings are indicated in bold ( all switches OFF ). • If the robust Xon setting is turned on with selector 8, the printer sends Xon signals at one second intervals to the connected computer until it receives data. It is effective only if selector 7 is set to the On position for the Xon/Xoff plus DTR setting. 2-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

2-6
Table 1: Serial Interface Parameters Settings
Selector
Parameters
On (up)
Off (down)
1
Baud Rate
See Table 2
2
Baud Rate
See Table 2
3
Data Length
7 bits
8 bits
4
Stop Bit
2 bits
1 bit
5
Parity
See Table 3.
6
Parity
See Table 3.
7
Protocol
Xon/Xoff + DTR
DTR only
8
Robust Xon
On
Off
Table 2: Baud Rate Settings
Selector 1
Selector 2
For RS-422A
For RS-232C
Off
Off
57600
9600
On
Off
9600
4800
Off
On
1200
1200
On
On
19200
19200
Table 3: Parity Settings
Selector 5
Selector 6
Parity
On
On
Odd
On
Off
Even
Off
Off
None
Note
The factory settings are indicated in bold ( all switches OFF ).
If the robust Xon setting is turned on with selector 8, the printer sends Xon
signals at one second intervals to the connected computer until it receives data. It
is effective only if selector 7 is set to the On position for the Xon/Xoff plus DTR
setting.