Page 72 highlights
Solution This corrected configuration should provide correct output. CMOS value for LPT1 is Standard Bi-directional LPT.VXD v4.00.503 file size 35,487. The LPT.VXD file is located in the Windows/System directory. The LPT.VXD file will be available from the Microsoft Web page. To change the CMOS settings: From Windows 95, click on Start Go to Programs Select Toshiba Utilities You will have either TSETUP or HARDWARE SETUP UTILITY For TSETUP Select Hardware Options Select Parallel/ Printer Select Standard bi-directional Click OK The computer will ask if you want to reboot-Select Yes On both utilities you will have to save and reboot the system. Note taht selecting standard Bi-directional changes the CMOS setting to bi-directional. Compaq Presario Problem A Compaq Presario running windows 95 will print only 3/4 page out of any Windows application. Cause This occurs with Windows 95, Windows 3.1, and Win95 minidrivers.