Synchronizing with an External Device, Open the [Genlock Adjustment] submenu.
View all Canon ME-200S SH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Synchronizing with an External Device Synchronizing with an External Device Using Genlock synchronization, you can synchronize this camera's video signal to that of an external video device. When a reference sync signal (analog blackburst or tri-level HD signal) is input through the GENLOCK terminal, the phases of the camera's V and H sync will automatically be synchronized to it. The phase difference between the external Genlock signal and the camera is initially set to 0. The H phase can be adjusted within the range of approximately ±0.4 H (-1023 to 1023). 59 BNC cable (commercially available) Reference sync signal 1 Open the [Genlock Adjustment] submenu. [Other Functions] > [Genlock Adjustment] 2 Push the joystick up/down to select the value of the first field and then press SET to move to the next field. • Change the rest of the fields in the same way to select the desired adjustment level (-1023 to 1023). 3 Select [Set] and then press SET. [Other Functions] [Genlock Adjustment] [000] NOTES • When a suitable Genlock signal is input, the Genlock synchronization stabilizes within approximately 10 seconds. • When a suitable Genlock signal is detected, [Gen.] will flash on the upper right of the screen. When the camera locks on the external Genlock signal, [Gen.] will stop flashing and stay on. • If the external Genlock signal is incorrect, the synchronization may not be stable.