Step2 Connection to the Network External power supply When using external power supply, use the Power Screwdriver Tightening torque: 0.2 N·m (max.) Connector (→ P.vii) supplied with the camera as shown on the right. Stripping length Supply 12VDC or 24VAC from a power supply insulated from 100-240VAC supply. You can connect 12VDC power supply without regard to the polarity. approx. 4mm - 6mm (0.16inch - 0.24inch) When using an external power supply, make sure that the voltage falls within the ranges below. AC24V: Voltage fluctuation within AC24V±10% Power Connector (Supplied) (within 50Hz or 60Hz±0.5Hz) Current supply capability over 1.0A per camera DC12V: Voltage fluctuation within DC12V±10% Current supply capability over 1.5A per camera * If using a DC12V battery power source, make sure to use the DC12V by connecting a resistor that is between 0.5 and 1.0Ω, and over 20W in series to the power supply line. Recommended power supply cables [reference] Cable (AWG) Conductor diameter (ømm) 12VDC Max. cable length (m) Max. cable length (ft) 24VAC Max. cable length (m) Max. cable length (ft) #24 (0.52mm) (0.020inch) 5 16.4 11 36.1 #22 (0.65mm) (0.026inch) 9 29.5 18 59.0 #20 (0.82mm) (0.032inch) 14 45.9 29 95.1 #18 (1.03mm) (0.041inch) 23 75.4 46 151.0 #16 (1.30mm) (0.051inch) 32 105.0 64 210.0 Use a UL cable (equivalent to UL-1015) for 12VDC or 24VAC. ● The camera head position is automatically initialized when the power is turned ON. ● Do not touch the camera head while its position is being initialized, or the Note head position may not be initialized correctly, or other malfunctions may occur. ● After turning off the camera, please wait at least 5 seconds before turning it on again. Turning the power back on within less than 5 seconds may cause a malfunction. When connecting and disconnecting the power, always observe the precautions given in "a Safety Precautions - Notes on PoE HUB" (→ P.xv). ● Read the manual of the PoE HUB for how to power it ON or OFF. ● You can connect an AC adapter (option) to a camera while it is powered using a PoE HUB. In this case, power is supplied using PoE, and the AC adapter is not used. When the PoE-supplied power is disconnected, the power supply automatically switches to the AC adapter. The network connection is now complete. 2-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

2-8
±
External power supply
When using external power supply, use the Power
Connector (
P.vii) supplied with the camera as shown
on the right.
Supply 12VDC or 24VAC from a power supply
insulated from 100-240VAC supply. You can connect
12VDC power supply without regard to the polarity.
When using an external power supply, make sure that
the voltage falls within the ranges below.
AC24V: Voltage fluctuation within AC24V
±
10%
(within 50Hz or 60Hz
±
0.5Hz)
Current supply capability over 1.0A per camera
DC12V: Voltage fluctuation within DC12V
±
10%
Current supply capability over 1.5A per camera
* If using a DC12V battery power source, make sure to use the DC12V by connecting a resistor
that is between 0.5 and 1.0
, and over 20W in series to the power supply line.
Step2 Connection to the Network
Screwdriver
Tightening torque:
0.2 N·m (max.)
Power
Connector
(Supplied)
Stripping length
approx. 4mm - 6mm
(0.16inch - 0.24inch)
The network connection is now complete.
Recommended power supply cables [reference]
Cable (AWG)
#24
#22
#20
#18
#16
Conductor diameter
(0.52mm)
(0.65mm)
(0.82mm)
(1.03mm)
(1.30mm)
(ømm)
(0.020inch)
(0.026inch)
(0.032inch)
(0.041inch)
(0.051inch)
12VDC
Max. cable length (m)
5
9
14
23
32
Max. cable length (ft)
16.4
29.5
45.9
75.4
105.0
24VAC
Max. cable length (m)
11
18
29
46
64
Max. cable length (ft)
36.1
59.0
95.1
151.0
210.0
Use a UL cable (equivalent to UL-1015) for 12VDC or 24VAC.
Note
The camera head position is automatically initialized when the power is turned ON.
Do not touch the camera head while its position is being initialized,
or the
head position may not be initialized correctly, or other malfunctions may occur.
After turning off the camera, please wait at least 5 seconds before turning it on
again. Turning the power back on within less than 5 seconds may cause a
malfunction. When connecting and disconnecting the power, always observe the
precautions given in “
a
Safety Precautions - Notes on PoE HUB” (
P.xv).
Read the manual of the PoE HUB for how to power it ON or OFF.
You can connect an AC adapter (option) to a camera while it is powered using a
PoE HUB. In this case, power is supplied using PoE, and the AC adapter is not
used. When the PoE-supplied power is disconnected, the power supply automatically
switches to the AC adapter.