Built-In Terminal External Device Output Terminals (OUT1, OUT2) The external device output terminal consists of two pairs of output terminals (OUT1, OUT2), which are nonpolar. The Viewer switches the 2 output terminals to disconnected or connected condition. The output terminals use photo couplers and are separate from the internal circuit in the VB-C60. A load to the output terminals should be within the following rated range: Rating across the output terminals: Max. 50VDC Continuous load current: 100mA or less Internal controller Internal Connection Chart 10k Ω 10k Ω 0.1µ F +3.3V 10k Ω External device + Input terminal IN1, IN2 External device - Output terminal OUT1, OUT2 The wire appropriate for external device cable is as follows. Tip Single wire AWG : # 28 - # 22 Conductor diameter: ø 0.32 - 0.65 mm (0.013 - 0.026 in) Strip the cables back roughly 8 or 9 mm (0.315 - 0.354 in). 3-6