Cisco 8540 User Guide - Page 50

AC Power Supply Specifications, Description, Specifications

Page 50 highlights

Appendix A Chassis and Power Supply Specifications Table A-1 Chassis and Power Supply Specifications (continued) Description Specifications Vibration, operating 5 to 200 Hz, 0.5 g (1 octet/min) Vibration, nonoperating 5 to 200 Hz, 1 g (1 octet/min) 200 to 500 Hz, 2 g (1 octet/min) Mean time between failures 7.1 years for system configuration Compliance CE Mark Maximum dissipated power at -48VDC Safety EMI8,9 1A UL 19502, CSA-C22.2 No. 9503, EN 609504, IEC 609505, TS 0016, AS/NZS 32607, EN 60825, IEC 60825, 21 CFR 1040 FCC10 Part 15 Class A (CFR 47), ICES11-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI12 Class A with UTP13 cables EN 55022 Class B; CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP14 cables AC Power Supply Specifications AC total output 1300W maximum AC voltage 100 to 240 VAC wide input with power factor correction Power supply load 1300W maximum configuration, 1000W typical with maximum configuration AC current Heat dissipation Rated 16 to 8A Maximum power budget: 17.6A @ 100 VAC, 60 Hz 14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully configured 1760W (6000 Btu/hr15) AC frequency 50 to 60 Hz Catalyst 8540 Chassis Installation Guide A-2 78-6134-03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Appendix A
Chassis and Power Supply Specifications
A-2
Catalyst 8540 Chassis Installation Guide
78-6134-03
Vibration, operating
5 to 200 Hz, 0.5 g (1 octet/min)
Vibration, nonoperating
5 to 200 Hz, 1 g (1 octet/min)
200 to 500 Hz, 2 g (1 octet/min)
Mean time between
failures
7.1 years for system configuration
Compliance
CE Mark
Maximum dissipated
power at –48VDC
1A
Safety
UL 1950
2
, CSA-C22.2 No. 950
3
, EN 60950
4
, IEC 60950
5
, TS 001
6
,
AS/NZS 3260
7
, EN 60825, IEC 60825, 21 CFR 1040
EMI
8
,
9
FCC
10
Part 15 Class A (CFR 47), ICES
11
-003 Class A, EN 55022
Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI
12
Class A
with UTP
13
cables
EN 55022 Class B; CISPR22 Class B, AS/NZS 3548 Class B, and VCCI
Class B with FTP
14
cables
AC Power Supply Specifications
AC total output
1300W maximum
AC voltage
100 to 240 VAC wide input with power factor correction
Power supply load
1300W maximum configuration, 1000W typical with maximum
configuration
AC current
Rated 16 to 8A
Maximum power budget: 17.6A @ 100 VAC, 60 Hz
14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully
configured
Heat dissipation
1760W (6000 Btu/hr
15
)
AC frequency
50 to 60 Hz
Table A-1
Chassis and Power Supply Specifications (continued)
Description
Specifications