B-11, Torquing Ground-Lug Screws
UPC - 882658187797
View all Cisco IE-3000-4TC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Appendix B Installation In a Hazardous Environment Figure B-11 Torquing Ground-Lug Screws Verifying Switch Operation 201696 1 1 Ground cable Step 7 Attach the other end of the ground wire to a grounded bare metal surface, such as a ground bus, a grounded DIN rail, or a grounded bare rack. Wiring the DC Power Source Read these warnings before wiring the DC power source: Caution This product is intended to be supplied by a Listed Class 2 power source marked with "Class 2" and rated from 18 to 60 VDC, 2.1 A. Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022 Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 5A. Statement 1005 Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074 OL-13017-01 Cisco IE 3000 Switch Hardware Installation Guide B-19