Connecting AC Power to the Power Converter, Step 3
UPC - 882658187797
View all Cisco IE-3000-4TC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Connecting the Switch to the Power Converter Figure 2-44 Connecting AC Power to the Power Converter Chapter 2 Switch Installation 1 2 3 202300 1 Ground 2 AC neutral 3 AC line Step 3 Tighten the ground wire terminal block screw. Note The torque should not exceed 10 in-lb. Step 4 Step 5 Insert the line and neutral wire leads into the terminal block line and neutral connections. See Figure 2-44. Make sure that you cannot see any wire lead. Ensure that only wire with insulation extends from the connectors. Tighten the line and neutral terminal block screws. Note The torque should not exceed 10 in-lb. Step 6 Replace the plastic cover over the terminal block. Step 7 Connect the other end of the AC power cord to the AC outlet. 2-50 Cisco IE 3000 Switch Hardware Installation Guide OL-13017-01