Symptoms and Solutions Chapter 6 Troubleshooting the System Hardware Table 6-8 Diagnostic-Panel LED Error Definitions (continued) Diagnostic-Panel LED Description Cause and Action DASD A hard disk drive error has occurred. The error pertains to DASD devices, which are not supported in the WAAS software. RAID A RAID controller error has occurred. 1. Check the RAID controller 2. Check the system error log. (See the "Viewing Error Logs" section on page 6-10.) FAN A fan has failed, is operating too Replace the failing fan. slowly, or has been removed. The LED next to the failing fan is on. A failing fan can also cause the TEMP LED to be lit. TEMP The temperature has exceeded one of the following thresholds: • The internal temperature for CPU1 or CPU2 has exceeded 207°F (97°C). • The ambient temperature has exceeded 104°F (40°C). 1. The ambient temperature must be within normal operating specifications. See the Appendix A, "Wide Area Application Engine Hardware Specifications." 2. Ensure that fans are operating correctly, and replace one if it has failed. 3. Ensure that the air vents are not blocked. A failing fan can cause the TEMP LED to be lit. 6-32 Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide OL-15012-02