Compaq ML310 User Guide - Page 83
Loose connections, Diagnostic steps, Action
UPC - 613326264973
View all Compaq ML310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Troubleshooting 83 Loose connections Action: • Be sure all power cords are securely connected. • Be sure all cables are properly aligned and securely connected for all external and internal components. • Remove and check all data and power cables for damage. Be sure no cables have bent pins or damaged connectors. • If a fixed cable tray is available for the server, be sure the cords and cables connected to the server are correctly routed through the tray. • Be sure each device is properly seated. • If a device has latches, be sure they are completely closed and locked. • Check any interlock or interconnect LEDs that may indicate a component is not connected properly. • If problems continue to occur, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage. Diagnostic steps To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section, "Start diagnosis flowchart (on page 84)," and follow the appropriate diagnostic path. If the other flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis flowchart (on page 86)." The General diagnosis flowchart is a generic troubleshooting process to be used when the problem is not server-specific or is not easily categorized into the other flowcharts. The available flowcharts include: • Start diagnosis flowchart (on page 84) • General diagnosis flowchart (on page 86) • Power-on problems flowchart (on page 88)