Dell 810 Owners Manual - Page 38
I1912 SEL full., LCD Log Full.
View all Dell 810 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Code Text Causes Corrective Actions E2112 Memory spared The system BIOS spared the Remove AC power to the on Card x memory because it system for 10 seconds and DIMM ##. determined that the restart the system. Power cycle memory has too many AC errors. If the problem persists, see "Troubleshooting System Memory" on page 169. E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC. The system BIOS disabled memory mirroring because it has determined one half of the mirror has had too many errors. "## & ##" represents the memory module pair implicated by the BIOS. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Troubleshooting System Memory" on page 169. I1910 Intrusion System cover removed. detected. Check chassis cover. Information only. I1911 LCD Log Full. Check SEL to review all Errors. LCD overflow message. A maximum of ten error messages can display sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events. Check the SEL for details on the events. Remove AC power to the system for 10 seconds or clear the SEL. I1912 SEL full. Review & clear log. The SEL is full of events and is unable to log any more. Check the SEL for more information and then clear the SEL. W1228 RAID Controller battery capacity < 24hr. Warns predictively that the Allow RAID battery to RAID battery has less than charge to greater than 24 24 hours of charge left. hours of sustained charge. If problem persists, replace the RAID battery. See "Installing the RAID Battery" on page 130. 38 About Your System