Dell Force10 S55T Quick Start Guide - Page 15

Environmental Parameters, AC Power Requirements, Power Supplies

Page 15 highlights

Environmental Parameters Parameter S55 Specifications S60 Specifications Temperature 32° to 104°F (0° to 40°C) 32° to 122°F (0° to 50°C) -40° to 158°F (-40° to 70°C) -40° to 158°F (-40° to 70°C) non-operating Maximum altitude No performance degradation No performance degradation to 10,000 feet (3,048 meters) to 10,000 feet (3,048 meters) Relative humidity 10 to 85% non-condensing 10 to 85% non-condensing 5 to 95% non-condensing (non-operating) Shock MIL-STD-810 MIL-STD-810 Vibration Bellcore GR-63 AC Power Requirements Parameter S55 Specifications Nominal Input Voltage 100 to 240 VAC, 47-63 Hz Maximum AC Power 5 A Supply Input Current Maximum System Power Input 135 W S60 Specifications 100 to 240 VAC, 50/60 Hz 2 A at 100/120 VAC 225W DC Power Requirements Parameter S55 Specifications S60 Specifications Nominal Input Voltage -43 to -72 VDC at startup -40 to - 60 VDC -36 to -72 VDC during normal operation Maximum Power 10 A Supply Input Current 3.6 A at -48 VDC Maximum System Power Input 135 W 225W Power Supplies The S55 and the S60 are designed to support two hot-swappable power supplies with integrated fans that provide the cooling for the chassis. Installing the Hardware 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Installing the Hardware
13
Environmental Parameters
AC Power Requirements
DC Power Requirements
Power Supplies
The S55 and the S60 are designed to support two hot-swappable power supplies
with integrated fans that provide the cooling for the chassis.
Parameter
S55 Specifications
S60 Specifications
Temperature
32° to 104°F (0° to 40°C)
-40° to 158°F (-40° to 70°C)
32° to 122°F (0° to 50°C)
-40° to 158°F (-40° to 70°C)
non-operating
Maximum altitude
No performance degradation
to 10,000 feet (3,048 meters)
No performance degradation
to 10,000 feet (3,048 meters)
Relative humidity
10 to 85% non-condensing
10 to 85% non-condensing
5 to 95% non-condensing
(non-operating)
Shock
MIL-STD-810
MIL-STD-810
Vibration
Bellcore GR-63
Parameter
S55 Specifications
S60 Specifications
Nominal Input Voltage
100 to 240 VAC, 47-63 Hz
100 to 240 VAC, 50/60 Hz
Maximum AC Power
Supply Input Current
5 A
2 A at 100/120 VAC
Maximum System
Power Input
135 W
225W
Parameter
S55 Specifications
S60 Specifications
Nominal Input Voltage
-43 to -72 VDC at startup
-36 to -72 VDC during normal
operation
–40 to – 60 VDC
Maximum Power
Supply Input Current
10 A
3.6 A at -48 VDC
Maximum System
Power Input
135 W
225W