Dell PowerConnect B - MLXe 4 Hardware Installation Guide - Page 111

Managing Routers and Modules, Managing the device

Page 111 highlights

Chapter Managing Routers and Modules 5 Managing the device You can perform these management tasks for the router: • Display status and temperatures of all hardware components. • Display the Syslog configuration and static and dynamic buffers. • Disable and re-enable power to interface modules Disabling and re-enabling power to interface modules You can disable power and re-enable power to all interface modules. or to a specified interface module using the power-off command in the CLI, as shown in this example. PowerConnect# power-off lp all Syntax: power-off lp [all |] • all - disables power to all interface modules • - disables power to the interface module in the specified slot. You can specify 1-4 for 4-slot routers, 1-8 for 8-slot routers, and 1-16 for 16-slot routers. NOTE It is recommended that you do not disable power to interface modules during a software upgrade. If you try to disable power during a software upgrade, the following message will be displayed: Warning: There is an outstanding software download. Do you want to continue ? (enter "Y" or "n") Type "n" and wait until the upgrade is complete. To re-enable power to all interfaces. or to a specific interface, enter the power-on ip command, as shown in this example: PowerConnect# power-on ip Syntax: power-on lp [all |] • all - enables power to all interface modules • disables power to the interface module in the specified slot. You can specify 1-4 for 4-slot routers, 1-8 for 8-slot routers and 1-16 for 16-slot routers. PowerConnect B-MLXe Hardware Installation Guide 99 53-1002111-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

PowerConnect B-MLXe Hardware Installation Guide
99
53-1002111-01
Chapter
5
Managing Routers and Modules
Managing the device
You can perform these management tasks for the router:
Display status and temperatures of all hardware components.
Display the Syslog configuration and static and dynamic buffers.
Disable and re-enable power to interface modules
Disabling and re-enabling power to interface modules
You can disable power and re-enable power to all interface modules. or to a specified interface
module using the
power-off
command in the CLI, as shown in this example.
PowerConnect# power-off lp all
Syntax:
power-off lp
[
all
|<
slot-number
>]
all
- disables power to all interface modules
<
slot number
> - disables power to the interface module in the specified slot. You can specify
1-4 for 4-slot routers, 1-8 for 8-slot routers, and 1-16 for 16-slot routers.
NOTE
It is recommended that you do not disable power to interface modules during a software upgrade.
If you try to disable power during a software upgrade, the following message will be displayed:
Warning: There is an outstanding software download.
Do you want to continue ? (enter “Y” or “n”)
Type “
n
” and wait until the upgrade is complete.
To re-enable power to all interfaces. or to a specific interface, enter the
power-on ip
command, as
shown in this example:
PowerConnect# power-on ip
Syntax:
power-on lp
[
all
|<
slot-number
>]
all
- enables power to all interface modules
<slot number> disables power to the interface module in the specified slot. You can specify 1-4
for 4-slot routers, 1-8 for 8-slot routers and 1-16 for 16-slot routers.