Dell PowerConnect B - MLXe 4 Hardware Installation Guide - Page 141

removed, and that there are enough bytes free to begin the upgrade., file has been

Page 141 highlights

Important software upgrade considerations 6 08/06/2008 03:42:12 07/30/2008 10:21:56 08/09/2008 09:03:14 08/10/2008 12:49:09 08/16/1908 06:38:47 08/15/1908 09:21:34 08/20/1908 12:38:45 08/21/1908 12:12:27 08/27/1908 11:25:18 08/31/1908 06:13:15 08/17/1908 14:10:29 08/27/1908 11:25:48 08/31/1908 06:13:43 08/31/1908 06:53:40 705 $$sshdsspub.key 1,712 $$sslcert.key 980,769 IMF.cfg 981,804 IMF1.cfg 2,663,857 ___mbridge 2,663,857 ___mbridge.old 123 boot-parameter 524,288 lp-monitor-0 3,335,554 lp-primary-0 3,304,730 lp-secondary-0 422,393 monitor 6,530,021 primary 6,244,777 secondary 981,549 startup-config 15 File(s) 0 Dir(s) 28,636,142 bytes 2,097,152 bytes free If necessary, you can delete the mbridge.old file to increase the available memory. Though unlikely, you may have to delete additional files for the upgrade to succeed. Contact Dell technical support before removing additional files. PowerConnect# delete___mbridge.old NOTE The file name delete___mbridge.old must contain three underscores. After deleting the mbridge.old file, enter to dir command to verify that the mbridge.old file has been removed, and that there are enough bytes free to begin the upgrade. PowerConnect# dir

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

PowerConnect B-MLXe Hardware Installation Guide
129
53-1002111-01
Important software upgrade considerations
6
08/06/2008 03:42:12
705 $$sshdsspub.key
07/30/2008 10:21:56
1,712 $$sslcert.key
08/09/2008 09:03:14
980,769 IMF.cfg
08/10/2008 12:49:09
981,804 IMF1.cfg
08/16/1908 06:38:47
2,663,857 ___mbridge
08/15/1908 09:21:34
2,663,857 ___mbridge.old
<<<<<<<<<<<<<
08/20/1908 12:38:45
123 boot-parameter
08/21/1908 12:12:27
524,288 lp-monitor-0
08/27/1908 11:25:18
3,335,554 lp-primary-0
08/31/1908 06:13:15
3,304,730 lp-secondary-0
08/17/1908 14:10:29
422,393 monitor
08/27/1908 11:25:48
6,530,021 primary
08/31/1908 06:13:43
6,244,777 secondary
08/31/1908 06:53:40
981,549 startup-config
15 File(s)
28,636,142 bytes
0 Dir(s)
2,097,152 bytes free
If necessary, you can delete the
mbridge.old
file to increase the available memory. Though unlikely,
you may have to delete additional files for the upgrade to succeed. Contact Dell technical support
before removing additional files.
PowerConnect# delete___mbridge.old
NOTE
The file name
delete___mbridge.old
must contain
three
underscores.
After deleting the
mbridge.old
file, enter to
dir
command to verify that the
mbridge.old
file has been
removed, and that there are enough bytes free to begin the upgrade.
PowerConnect# dir
<<<<<
Directory of /flash/
08/31/1908 13:26:14
3 $$snmp_boots
08/06/2008 03:42:12
705 $$sshdsspub.key
07/30/2008 10:21:56
1,712 $$sslcert.key
08/09/2008 09:03:14
980,769 IMF.cfg
08/10/2008 12:49:09
981,804 IMF1.cfg
08/16/1908 06:38:47
2,663,857 ___mbridge
<<<<<<<<<<<<<<<<<<<<<mbridge.old file is removed
08/20/1908 12:38:45
123 boot-parameter
08/21/1908 12:12:27
524,288 lp-monitor-0
08/27/1908 11:25:18
3,335,554 lp-primary-0
08/31/1908 06:13:15
3,304,730 lp-secondary-0
08/17/1908 14:10:29
422,393 monitor
08/27/1908 11:25:48
6,530,021 primary
08/31/1908 06:13:43
6,244,777 secondary
08/31/1908 06:53:40
981,549 startup-config
14 File(s)
25,972,285 bytes
0 Dir(s)
4,718,592 bytes free
You must also delete the
mbridge.old
file from the redundant management module, if one is
installed. To access the redundant management module, enter the
switchover
command to make it
the active management module.