Dell PowerConnect Brocade M5424 Brocade 7.1.0 Fabric OS Command Reference Guid - Page 285
errDelimiterSet, errFilterSet, errShow, errdump --count 3, errdump --message EM-5012
View all Dell PowerConnect Brocade M5424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 285 highlights
errDump 2 SEE ALSO To display messages based on count value: switch:admin> errdump --count 3 Fabric OS: v7.1.0errDump 2012/06/18-20:23:09, [LOG-1003], 1, SLOT 5 | CHASSIS, INFO, \ pluto_19, The log has been cleared. 2012/06/18-20:24:52, [SULB-1001], 2, SLOT 5 | CHASSIS, WARNING, \ pluto_19, Firmwaredownload command has started. 2012/06/18-20:24:52, [SULB-1036], 3, SLOT 5 | CHASSIS, INFO, \ pluto_19, The current Version: Fabric OS v7.1.0_rasadmin To display raslog messages based on a message ID: switch:admin> errdump --message EM-5012 Msg Id recieved = EM-5012 Fabric OS: v7.1.0errdump_opt_add 2012/10/17-05:45:28:562789, [EM-5012], 0, CHASSIS, INFO, chassis_1, \ start emd FSS_RECOV_WARM, emfss.c, line: 216, comp:emd, \ ltime:2012/10/17-05:45:28:562618 2012/10/17-05:45:31:120123, [EM-5012], 0, CHASSIS, INFO, chassis_1, \ end emd FSS_RECOV_ACTIVE (warm), emfss.c, line: 486, comp:emd, \ ltime:2012/10/17-05:45:31:120114 2012/10/17-05:45:33:423814, [EM-5012], 0, CHASSIS, INFO, chassis_1, \ EM: sent chassis ready event., em.c, line: 2200, comp:emd, \ ltime:2012/10/17-05:45:33:423804 2012/10/17-05:45:33:424052, [EM-5012], 0, CHASSIS, INFO, chassis_1, \ EM: called fss_notify_status., em.c, line: 2225, comp:emd, \ ltime:2012/10/17-05:45:33:424043 errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference 257 53-1002746-01