Dell PowerEdge M520 Dell 10Gb Ethernet Pass Through II for M1000e Software Use - Page 18

Synopsis, Description, Example

Page 18 highlights

Rev 1.00 3.8.2 Software User's Manual cr_write (ADMIN) Synopsis: cr_write device_number 0xaddress 0xdata Description: Write data to an internal register on a PhyX device. This command accepts the following parameters: >device_number - the device to which memory the data should be written >address - memory location of the internal register (32-bit address) >data - the data to be written to the internal register Example: cr_write 1 0xf0010 0x1 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Software User’s Manual
Rev 1.00
18
3.8.2
cr_write (ADMIN)
Synopsis:
cr_write
device_number
0x
address
0x
data
Description:
Write data to an internal register on a PhyX device. This command accepts the following
parameters:
>device_number – the device to which memory the data should be written
>address – memory location of the internal register (32-bit address)
>data – the data to be written to the internal register
Example:
cr_write 1 0xf0010 0x1