Rev 1.00 3.8.2 Software User's Manual cr_write (ADMIN) Synopsis: cr_write device_number 0xaddress 0xdata Description: Write data to an internal register on a PhyX device. This command accepts the following parameters: >device_number - the device to which memory the data should be written >address - memory location of the internal register (32-bit address) >data - the data to be written to the internal register Example: cr_write 1 0xf0010 0x1 18
Software User’s Manual
Rev 1.00
18
3.8.2
cr_write (ADMIN)
Synopsis:
cr_write
device_number
0x
address
0x
data
Description:
Write data to an internal register on a PhyX device. This command accepts the following
parameters:
>device_number – the device to which memory the data should be written
>address – memory location of the internal register (32-bit address)
>data – the data to be written to the internal register
Example:
cr_write 1 0xf0010 0x1