Dell PowerEdge R7525 EMC PowerEdge RAID Controller S150 Users Guide - Page 7
Table 2. SATA specifications for PERC S150 continued
![]() |
View all Dell PowerEdge R7525 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Table 2. SATA specifications for PERC S150 (continued) Specification PERC S150 Software-based RAID for SATA drives Windows RAID: Volume, RAID 0, RAID 1, RAID 5 and RAID 10 Linux RAID: RAID 1 NOTE: After the operating system is installed on a RAID 1 disk, you can create non-boot virtual disks of any RAID level supported by the installed Linux operating system using native Linux RAID utilities. Pass-through SSD support Yes Table 3. NVMe specifications for PERC S150 Specification Maximum number of namespaces supported PERC S150 1 NOTE: If the drive having more than one namespaces is connected, the drive is marked offline and is inaccessible. NVMe connectors PCIe/slimline NOTE: Only Dell-compliant NVMe PCIe SSD 2.5-inch small form factor (SFF), or NVMe PCIe SSD adapter cards are supported. Dell-compliant NVMe compatibility Yes Communication with end devices PCIe Software-based RAID for NVMe PCIe SSDs Windows RAID: Volume, RAID 0, RAID 1, RAID 5, and RAID 10 Linux RAID: RAID 1 NOTE: After the operating system is installed on a RAID 1 disk, you can create non-boot virtual disks of any RAID level supported by the installed Linux operating system using native Linux RAID utilities. Pass-through NVMe PCIe SSD support Yes The following table provides PERC S150 virtual disk specifications: Table 4. Virtual disk specifications for PERC S150 with SATA configuration Specification PERC S150 Maximum number of physical disks supported 8 Maximum number of virtual disks supported 30 NOTE: The maximum number of virtual disks may exceed 30 when physical disks are migrated from any other configuration or a disk in Ready state is converted to a non-RAID disk. Maximum number of virtual disks supported from a single disk 8 group NOTE: PERC S150 does not restrict the creation of 8 virtual disks per disk group. It allows you to create upto 30 virtual disks. Minimum virtual disk size Maximum number of physical disks per virtual disk Maximum number of virtual disks per physical disk Maximum number of physical disks in a volume Maximum number of physical disks in a RAID 0 Maximum number of physical disks in a RAID 1 Maximum number of physical disks in a RAID 5 102 MB 8 8 1 8 2 8 Overview 7
![](/manual_guide/products/dell-poweredge-c6525-emc-poweredge-raid-controller-s150-users-guide-6a5d420/7.png)