Dell S3048-ON VxFlex Network Deployment Guide using EMC Networking 25GbE switc - Page 13

GbE OOB Management, S5248F-ON, Leaf1A, OOB Management

Page 13 highlights

S3048-ON OOB Management 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 S5248F-ON Leaf1A S5248F-ON Leaf1B GRN =10G ACT/ LNK A GRN =10G ACT/ LNK B VxFlex-1 Ready Node 1GbE OOB Management OOB management network connections Figure 8 shows the first node (VxFlex-1) connected to the S3048-ON management switch using the onboard iDRAC port. The connections for VxFlex-2 through VxFlex-4 (not shown) are done in the same manner. The production switches are also connected to the S3048-ON management switch using the OOB port on the back of each switch. The leaf switches are configured as a VLT pair. Part of a successful VLT deployment is the use of a VLT backup link. The backup link monitors the connectivity between the VLT peer switches. The backup link sends configurable, periodic, keepalive messages between the VLT peer switches. The out-of-band (OOB) management interface (mgmt1/1/1) is configured as a backup link to fulfill this requirement. Note: An existing 1GbE Base-T switch may be used as an alternative to the S3048-ON. Optionally, for small deployments, the dedicated iDRAC port on each Ready Node may be connected to a port configured on the in-band management VLAN on either one of the two S5248F-ON leaf switches. This requires an SFP-1GbE Base-T adapter, Dell EMC part number XTY28, for each iDRAC connection. 13 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

13
VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
51
52
49
50
GRN=10G
ACT/ LN K A
GRN=10G
ACT/ LN K B
1GbE OOB Management
S5248F-ON
Leaf1A
S5248F-ON
Leaf1B
VxFlex-1
S3048-ON
OOB Management
Ready Node
OOB management network connections
Figure 8 shows the first node (VxFlex-1) connected to the S3048-ON management switch using the onboard
iDRAC port. The connections for VxFlex-2 through VxFlex-4 (not shown) are done in the same manner. The
production switches are also connected to the S3048-ON management switch using the OOB port on the
back of each switch.
The leaf switches are configured as a VLT pair. Part of a successful VLT deployment is the use of a VLT
backup link. The backup link monitors the connectivity between the VLT peer switches. The backup link sends
configurable, periodic, keepalive messages between the VLT peer switches. The out-of-band (OOB)
management interface (mgmt1/1/1) is configured as a backup link to fulfill this requirement.
Note:
An existing 1GbE Base-T switch may be used as an alternative to the S3048-ON. Optionally, for small
deployments, the dedicated iDRAC port on each Ready Node may be connected to a port configured on the
in-band management VLAN on either one of the two S5248F-ON leaf switches. This requires an SFP-1GbE