Dell S4148U-ON EMC Networking OS10EE FCoE Deployment with FSB - Page 21

Con uplink failure detection UFD

Page 21 highlights

5.2.10 Configure uplink failure detection (UFD) UFD is recommended on all server interfaces. Finally, exit configuration mode and save the configuration with the end and write memory commands. S5248-Leaf1 uplink-state-group 1 name "UFD_Group_1" downstream ethernet1/1/31-1/1/34 upstream ethernet1/1/53-1/1/54 enable end write memory S5248-Leaf2 uplink-state-group 1 name "UFD_Group_1" downstream ethernet1/1/31-1/1/34 upstream ethernet1/1/53-1/1/54 enable end write memory 21 Dell EMC Networking OS10EE FCoE Deployment with FSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

21
Dell EMC Networking OS10EE FCoE Deployment with FSB
5.2.10
Configure uplink failure detection (UFD)
UFD is recommended on all server interfaces.
Finally, exit configuration mode and save the configuration with the
end
and
write memory
commands.
S5248-Leaf1
S5248-Leaf2
uplink-state-group 1
name "UFD_Group_1"
downstream ethernet1/1/31-1/1/34
upstream ethernet1/1/53-1/1/54
enable
end
write memory
uplink-state-group 1
name "UFD_Group_1"
downstream ethernet1/1/31-1/1/34
upstream ethernet1/1/53-1/1/54
enable
end
write memory