Dell S4148U-ON EMC Networking OS10EE FCoE Deployment with FSB - Page 37

:F4:E9:D4:62:4B:BA, 01:F4:E9:D4:62:4B:BB, 01:F4:E9:D4:62:4B:72, 01:F4:E9:D4:62:4B:73

Page 37 highlights

The FC WWPNs used in this deployment example are shown in Table 1. The Switch column has been added for reference per the cable connections in the SAN topology diagram (Figure 7). Server FCoE CNA port WWPNs Server Port Switch WWPN R740xd-1 1 S4148U-Leaf1 20:01:F4:E9:D4:61:C6:6A R740xd-1 2 S4148U-Leaf2 20:01:F4:E9:D4:61:C6:6B R740xd-2 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4A:D0 R740xd-2 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4A:D1 R740xd-3 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4B:BA R740xd-3 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4B:BB R740xd-4 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4B:72 R740xd-4 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4B:73 B.2 Dell EMC Unity 500F storage array configuration The WWPNs of FC adapters in storage arrays are also used for FC zone configuration. WWPNs on Unity storage arrays are determined as follows: 1. Connect to the Unisphere GUI in a web browser and log in. Click the Settings icon right corner of the page. 2. In the left pane of the Settings window, select Access > Fibre Channel. near the top The Fibre Channel Ports page is displayed as shown in Figure 11. A zoomed-in view of the area inside the red box is shown in Figure 12. Unisphere Fibre Channel Ports page Zoomed-in view of SP A and SP B WWNs on Fibre Channel Ports page 37 Dell EMC Networking OS10EE FCoE Deployment with FSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

37
Dell EMC Networking OS10EE FCoE Deployment with FSB
The FC WWPNs used in this deployment example are shown in Table 1. The
Switch
column has been added
for reference per the cable connections in the SAN topology diagram (Figure 7).
Server FCoE CNA port WWPNs
Server
Port
Switch
WWPN
R740xd-1
1
S4148U-Leaf1
20:01:F4:E9:D4:61:C6:6A
R740xd-1
2
S4148U-Leaf2
20:01:F4:E9:D4:61:C6:6B
R740xd-2
1
S4148U-Leaf1
20:01:F4:E9:D4:62:4A:D0
R740xd-2
2
S4148U-Leaf2
20:01:F4:E9:D4:62:4A:D1
R740xd-3
1
S4148U-Leaf1
20:01:F4:E9:D4:62:4B:BA
R740xd-3
2
S4148U-Leaf2
20:01:F4:E9:D4:62:4B:BB
R740xd-4
1
S4148U-Leaf1
20:01:F4:E9:D4:62:4B:72
R740xd-4
2
S4148U-Leaf2
20:01:F4:E9:D4:62:4B:73
B.2
Dell EMC Unity 500F storage array configuration
The WWPNs of FC adapters in storage arrays are also used for FC zone configuration. WWPNs on Unity
storage arrays are determined as follows:
1.
Connect to the Unisphere GUI in a web browser and log in. Click the
Settings
icon
near the top
right corner of the page.
2.
In the left pane of the
Settings
window, select
Access > Fibre Channel
.
The
Fibre Channel Ports
page is displayed as shown in Figure 11. A zoomed-in view of the area inside the
red box is shown in Figure 12.
Unisphere Fibre Channel Ports page
Zoomed-in view of SP A and SP B WWNs on Fibre Channel Ports page