S4148U-ON FCF F_Port validation

Page 29 highlights

8 8.1 8.2 8.3 S4148U-ON FCF (F_Port) validation After configuring connected devices, many commands are available to validate the network configuration. This section provides a list of the most common commands and their output for this topology. Note: The following commands and outputs are for the S4148U-F-Port-1. The output for the S4148U-F-Port-2 is similar. For more commands and outputs related to the leaf-spine portion of the topology, such as VLT, and BGP, see Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE. show interface status The show interface status | grep up command is used to verify that the required interfaces are up, and links are established at their appropriate speeds. S4148U-F-Port-1# show interface status | grep up Port Description Status Speed Duplex Eth 1/1/41 up 10G full Fc 1/1/1 up 16G auto Fc 1/1/3 up 16G auto Mode Vlan Tagged-Vlans A 1 - show vlan The show vlan command is used to verify configured VLANs and the interfaces they are applied to. S4148U-F-Port-1# show vlan Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs, @ - Attached to Virtual Network Q: A - Access (Untagged), T - Tagged NUM Status Description Q Ports * 1 Active A Eth1/1/9-1/1/26,1/1/29-1/1/54 1001 Active T Eth1/1/41 show fcoe system The show fcoe system command is used to show FCoE-related information. S4148U-F-Port-1# show fcoe system Mode : FPORT FCOE VLAN List (Operational) : 1001 FCFs : 1 Enodes : 4 Sessions : 4 29 Dell EMC Networking OS10EE FCoE Deployment with FSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

29
Dell EMC Networking OS10EE FCoE Deployment with FSB
8
S4148U-ON FCF (F_Port) validation
After configuring connected devices, many commands are available to validate the network configuration.
This section provides a list of the most common commands and their output for this topology.
Note:
The following commands and outputs are for the S4148U-F-Port-1. The output for the S4148U-F-Port-2
is similar. For more commands and outputs related to the leaf-spine portion of the topology, such as VLT, and
BGP, see
Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE
.
8.1
show interface status
The
show interface status | grep up
command is used to verify that the required interfaces are up,
and links are established at their appropriate speeds.
S4148U-F-Port-1#
show interface status | grep up
Port
Description
Status
Speed
Duplex
Mode Vlan Tagged-Vlans
Eth 1/1/41
up
10G
full
A
1
-
Fc 1/1/1
up
16G
auto
-
Fc 1/1/3
up
16G
auto
-
8.2
show vlan
The
show vlan
command is used to verify configured VLANs and the interfaces they are applied to.
S4148U-F-Port-1#
show vlan
Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs,
@ – Attached to Virtual Network
Q: A - Access (Untagged), T - Tagged
NUM
Status
Description
Q Ports
*
1
Active
A Eth1/1/9-1/1/26,1/1/29-1/1/54
1001
Active
T Eth1/1/41
8.3
show fcoe system
The
show fcoe system
command is used to show FCoE-related information.
S4148U-F-Port-1#
show fcoe system
Mode
: FPORT
FCOE VLAN List (Operational) : 1001
FCFs
: 1
Enodes
: 4
Sessions
: 4