Dell Wyse 3020 Wyse ThinOS Version 8.5 INI Reference Guide - Page 39

ExpireTime, UnlockRefresh, SCShowCNName, SCSecurePINEntry, AutoConnectTimeout, DisableEditDomain

Page 39 highlights

ExpireTime - Specifies the signon expiration time. The range is 0 to 480 minutes. The default is 0 which means no expiration. If the value is larger than 480, then 480 is set instead. If the value is smaller than 0, then 0 is set instead. After system signon or starting a connection, the expiration time starts counting. Once the expiration time is reached, starting a connection by clicking the icon, menu or connection manager, will bring up a pop up message box to enter the password. Only if the password is same as the original signon password, the session starts. If the terminal is locked and unlocked with the password, the signon expiration time starts counting again. UnlockRefresh - Default is yes. Yes/no option to specifies the refresh action after unlocking the system in classic mode. Yes - While unlocking, the system will refresh the PNA list to verify the password. No - Disables refresh. SCShowCNName - Default is yes. Yes/no option to force the use of the CN name of the certificate as the user name when using smartcard signon. The default uses the UPN name as the user name. SCSecurePINEntry - Default is no. Yes/no option to enable Secure PIN entry function for pkcs15 smart card with Cherry keyboard. AutoConnectTimeout- Default is 30 seconds. This option sets the timeout for auto connect published application. The range is 10 seconds to 300 seconds. DisableEditDomain- The optional keyword DisableEditDomain, is set to yes to stop typing in the domain box manually. Typing the character @ or \ as in the format domain\user and user@domain in the username box are not allowed. AdGroupPreFix- The option AdGroupPreFix is only valid, when you configure SignOn=NTLM. If the option is configured, then the thin client verifies the names of all AD groups to which a sign-on user belongs, to get the first group name so that its prefix matches adgrpnameprefix, and load adgroup/"the_whole_ad_group_name".ini, if the configuration file exists, before loading the user specific INI. For example, if the sign on user is user_111 in a domain, and the user_111 belongs to group domain user and group tc_grp1_ad, the option is configured as AdGroupPrefix=tc_grp1. If the configuration file adgroup/tc_grp1_ad.ini is available, it will be loaded. ClearUser-The option keyword ClearUser, if set to yes, clears the username when login fails, and if set to no, retains username entered after login failure. The default value is no. DisableSignoff-The option keyword DisableSignoff, if set to yes, disables signoff button from shutdown and connection manager window. Also this parameter disables the logoff button on StoreFront desktop. SFZeroButtons-The option keyword SFZeroButtons. if set to yes, displays the buttons (shutdown, login and so on) at the bottom of signon window, such as Zero mode when set StoreFront style. Parameters for wnos INI files only 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

ExpireTime
Specifies
the signon expiration time. The range is 0
to 480 minutes. The default is
0
which means no expiration.
If the value is larger than 480, then 480 is set instead. If the value is
smaller than 0, then 0 is set instead.
After system signon or starting a connection, the expiration time
starts counting. Once the expiration time is reached, starting a
connection by clicking the icon, menu or connection manager, will
bring up a pop up message box to enter the password. Only if the
password is same as the original signon password, the session
starts.
If the terminal is locked and unlocked with the password, the signon
expiration time starts counting again.
UnlockRefresh
— Default is
yes
. Yes/no option to
specifies
the
refresh action after unlocking the system in classic mode.
Yes — While unlocking, the system will refresh the PNA list to
verify the password.
No — Disables refresh.
SCShowCNName
— Default is
yes
. Yes/no option to force the use
of the CN name of the
certificate
as the user name when using
smartcard signon. The default uses the UPN name as the user
name.
SCSecurePINEntry
— Default is
no
. Yes/no option to enable
Secure PIN entry function for pkcs15 smart card with Cherry
keyboard.
AutoConnectTimeout
— Default is
30
seconds.
This option sets the timeout for auto connect published
application. The range is 10 seconds to 300 seconds.
DisableEditDomain
— The optional keyword DisableEditDomain, is
set to yes to stop typing in the domain box manually. Typing the
character @ or \ as in the format domain\user and user@domain in
the username box are not allowed.
AdGroupPreFix
— The option AdGroupPreFix is only valid, when
you
configure
SignOn=NTLM. If the option is
configured,
then the
thin client
verifies
the names of all AD groups to which a sign-on
user belongs, to get the
first
group name so that its
prefix
matches
adgrpnameprefix,
and load
adgroup/"the_whole_ad_group_name".ini, if the
configuration
file
exists, before loading the user
specific
INI.
For example, if the sign on user is user_111 in a domain, and the
user_111 belongs to group domain user and group tc_grp1_ad, the
option is
configured
as
AdGroupPrefix=tc_grp1.
If the
configuration
file
adgroup/tc_grp1_ad.ini is available, it will be loaded.
ClearUser
—The option keyword ClearUser, if set to yes, clears the
username when login fails, and if set to no, retains username
entered after login failure. The default value is no.
DisableSignoff
—The option keyword
DisableSignoff,
if set to yes,
disables
signoff
button from shutdown and connection manager
window. Also this parameter disables the
logoff
button on
StoreFront desktop.
SFZeroButtons
—The option keyword SFZeroButtons. if set to yes,
displays the buttons (shutdown, login and so on) at the bottom of
signon window, such as Zero mode when set StoreFront style.
Parameters for wnos INI
files
only
39