Denon DCM-5001 Serial Protocol - Page 27

Request TOC Data

Page 27 highlights

.17 Request TOC Data This requests TOC data from the disc in a specified zone. bytebit 7 6 5 4 3 2 1 0 0 STX 02h 1 Command code 1 2 Zone specification (*1) 3 ETX 03h 4 BCCH high-level 5 BCCL low-level (*1) Zone specification Code 31h1 32h2 Single zone Current zone Next zone Function Dual zone Zone 1 Zone 2 Answers returned bytebit 7 6 5 4 3 2 1 0 0 STX 02h 1 Reply code 1 2 Answer code 3 Top track number ( 10 digits ) 4 Top track number ( 1 digits ) 5 Final track number ( 10 digits ) 6 Final track number ( 1 digit ) 7 Absolute starting time for read-out area ( minutes10 digits ) 8 Absolute starting time for read-out area ( minutes1 digit ) 9 Absolute starting time for read-out area ( second10 digits ) 10 Absolute starting time for read-out area ( second1 digit ) 11 Starting time for read-out area ( frame10 digits ) 12 Starting time for read-out area ( frame1 digit ) 13 Absolute starting time for top track ( minutes10 digits ) 14 Absolute starting time for top track ( minutes1 digit ) 15 Absolute starting time for top track ( second10 digits ) 16 Absolute starting time for top track ( second1 digit ) 17 Absolute starting time for top track ( frame10 digits ) 18 Absolute starting time for top track ( frame1 digit ) 19 ETX 03h 20 BCCH high-level 21 BCCL low-level Special condition · This command is valid only when the zone status is TOC Read (E) or Load CD-TEXT Disc (J), or when the previous zone status is proceeded to other status by the Request System Status command or other commands see item 3 of "1.8 List of Status Codes". · The TOC Read OK and Load CD-TEXT Disc statuses proceed to the next statuses by sending this command. Other

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

.17
Request TOC Data
This requests TOC data from the disc in a specified zone.
bytebit
7
6
5
4
3
2
1
0
0
STX 02h
1
Command code
1
2
Zone specification (*1)
3
ETX 03h
4
BCCH high-level
5
BCCL low-level
(*1) Zone specification
Code
Function
Single zone
Dual zone
31h1
Current zone
Zone 1
32h2
Next zone
Zone 2
Answers returned
bytebit
7
6
5
4
3
2
1
0
0
STX 02h
1
Reply code
1
2
Answer code
3
Top track number ( 10 digits )
4
Top track number ( 1 digits )
5
Final track number ( 10 digits )
6
Final track number ( 1 digit )
7
Absolute starting time for read-out area ( minutes10 digits )
8
Absolute starting time for read-out area ( minutes1 digit )
9
Absolute starting time for read-out area ( second10 digits )
10
Absolute starting time for read-out area ( second1 digit )
11
Starting time for read-out area ( frame10 digits )
12
Starting time for read-out area ( frame1 digit )
13
Absolute starting time for top track ( minutes10 digits )
14
Absolute starting time for top track ( minutes1 digit )
15
Absolute starting time for top track ( second10 digits )
16
Absolute starting time for top track ( second1 digit )
17
Absolute starting time for top track ( frame10 digits )
18
Absolute starting time for top track ( frame1 digit )
19
ETX 03h
20
BCCH high-level
21
BCCL low-level
Special condition
This command is valid only when the zone status is TOC Read (E) or Load CD-TEXT Disc (J),
or when the previous zone status is proceeded to other status by the Request System Status command
or other commands see item 3 of
1.8 List of Status Codes
.
The TOC Read OK and Load CD-TEXT Disc statuses proceed to the next statuses by sending
this command.
Other