Denon DN S5000 Quick Start Guide - Page 25

PRESET, Preset mode, Preset items and data - platter

Page 25 highlights

14 PRESET 1. Preset mode q The preset mode is available when PRESET button is pushed for more than 1 sec while DN-S5000 is in Cue, pause or no disc mode. w Turn the PARAMETERS knob to select the preset item. e After selecting an item, push the PARAMETERS knob to select the preset data. r To change other Preset items, repeat these steps. t Push the PRESET, CUE or PLAY/PAUSE (13) button to exit from the Preset mode. 2. Preset items and data The "*" mark next to the data indicates the default value. (1) AUTO CUE : Auto Cue level search on/off. (ON* / OFF) (2) PITCH RANGE : Select the playing pitch range when the power is turned on. (±4 / ±10* / ±16 / ±24%) (3) ALPHA-TRACK OUTPUT : Alpha-Track playback output destination. (Main out* / Alpha out) (4) PLATTER : Select whether or not the Platter is to rotate during playback. (Turn round* / Turn stop) (5) PLATTER MODE MEMO : When the Platter mode (DRAG-S, BRAKE and ECHO) parameters, the source and the on/off setting are stored, the stored data is set each time the power is turned on. q To set the effect data, push the PARAMETERS knob and select "YES". • "Set OK?" flashes on the character display. w Push the PARAMETERS knob again and select "OK" to execute setting the data. e Once setting is completed, "Complete!" is displayed. (6) AUTO LOAD : Time for automatically loading disc. (OFF / 10 / 30 / 60* seconds) (7) EOM : Track end message start time. (OFF / 10* / 15 / 20 / 30 / 60 / 90 seconds) (8) DIGITAL OUT OUTPUT LEVEL : Select the digital out output level. (Normal* / -6 dB Down) NOTE: Use -6dB if the playback output is clipped when the Main and Alpha-Tracks are played simultaneously at the same position. (9) FADER START MODE: Select 2-line type (Cue and Play) or 1 line type (Play and Pause). (Play /Cue* / Play/Pause) (10) POWER ON PLAY : Playback starts when the power is turned on if a disc is loaded. (On / Off*) (11) A3/4 MODE : Select the A3 and A4 button operating modes when the power is turned on. (Sampler* / 4H/S / Alpha-Track H/S) (12) SINGLE/CONTINUOUS : Select the play mode when the power is turned on. (Single* / Continuous) (13) ELAPSED/REMAIN: Select the time mode when the power is turned on. (Elapsed* / Remain) (14) PROGRAM ALL CLEAR : Clear all program play data in the non-volatile memory. q To clear the program, push the PARAMETERS knob and select "YES". • "Clear OK?" flashes on the character display. w Push the PARAMETERS knob again and select "OK" to execute clearing the program. "Prog. Clear" is displayed on the character display while data clearing. e Once clearing is completed, "Complete!" is displayed. (15) MEMO ALL CLEAR : Clear all MEMO data in the non-volatile memory. q To clear all MEMO data, push the PARAMETERS knob and select "YES". • "Clear OK?" flashes on the character display. w Push the PARAMETERS knob again and select "OK" to execute clearing all MEMO data. • "Memo Clear" is displayed on the character display while clearing. e Once clearing is completed, "Complete!" is displayed. ENGLISH (16) MEMO ALL COPY : Copy all MEMO data from the master unit of DN-S5000 (or DN-D9000, DN-2600F) to the slave unit of DN-S5000 (or DN-D9000) when both unit are connected by the normal straight Cable. (See diagram for the cable.) NOTE: Be sure CD player have no discs inside. A straight cable used: X'EFFECT OUT DN-S5000 DN-S5000 (X'EFFECT IN) DN-D9000 (X'EFFECT) DN-2600F (X'EFFECT) • Using the straight cable, connect the X-EFFECT terminals between two DN-S5000 units or between one DN-2600F and one DN-S5000 unit or between one DN-D9000 and one DN-S5000 unit. • If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F beforehand. (For details, refer to the DN-2600F's operating instructions.) ✽ Set the "Copy Master" for the Preset item (14). Then, step to the q below on the slave unit of DN-S5000. • Copying can be performed using the DN-S5000 and DN-D9000 in the same way as when using two units of the DN-S5000. DN-S5000-1 DN-S5000-2 POWER ON OFF DIGITAL OUT IN LL MAIN RR OUT LINE OUT MONITOR X-EFFECT OUT jack X-EFFECT ALPHA MAIN FADER X-EFFECT ALPHA MAIN FADER POWER ON OFF DIGITAL OUT IN LL MAIN RR OUT LINE OUT MONITOR X-EFFECT IN jack 3.5 mm stereo mini cord • Perform the copying operation as below on the slave unit of DN-S5000. q To start copying, push the PARAMETERS knob and select "YES". Now "Copy OK?" messages flashes on the character display. w Push the PARAMETERS knob again to confirm. Now "Start OK?" is displayed. NOTE: If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F here. In the Preset item (15), first start copying on the DN-2600F. Then, step to e below on the slave unit of DN-S5000. e Push the PARAMETERS knob once again, and the unit starts copying when the MEMO data are received from the master unit. Now "Copying" is displayed. • If the master unit and the slave unit are not connected properly or the DN-2600F is not prepared to start sending data, "Not Connect" is displayed on the character display. r When copying is completed correctly, "Complete!" is displayed. • "Copy Error" is displayed on the character display if copying was not completed correctly. In this case, try the above procedure again. • The copied MEMO data are added to the highest number area of the slave DN-S5000 unit. (17) The DN-S5000's software version is displayed. (SYSTEM / DSP / CD DRIVE) (18) PRESET CLEAR : Set all the preset data back to the factory defaults. q To clear the PRESET data, push the PARAMETERS. "Initial OK?" flashes on the character display. w Push the PARAMETERS knob again and select "OK" to start clear the preset data. "Preset Int" is displayed on the character display while data clearing. e Once clearing is completed, "Complete!" is displayed. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

23
ENGLISH
14
PRESET
1.
Preset mode
q
The preset mode is available when PRESET button is pushed for more than 1 sec while DN-S5000 is in
Cue, pause or no disc mode.
w
Turn the PARAMETERS knob to select the preset item.
e
After selecting an item, push the PARAMETERS knob to select the preset data.
r
To change other Preset items, repeat these steps.
t
Push the PRESET, CUE or PLAY/PAUSE (
13
) button to exit from the Preset mode.
2.
Preset items and data
The
*
mark next to the data indicates the default value.
(1)
AUTO CUE : Auto Cue level search on/off. (ON* / OFF)
(2)
PITCH RANGE : Select the playing pitch range when the power is turned on. (±4 / ±10* / ±16 / ±24%)
(3)
ALPHA-TRACK OUTPUT : Alpha-Track playback output destination. (Main out* / Alpha out)
(4)
PLATTER : Select whether or not the Platter is to rotate during playback. (Turn round* / Turn stop)
(5)
PLATTER MODE MEMO :
When the Platter mode (DRAG-S, BRAKE and ECHO) parameters, the source and the on/off setting
are stored, the stored data is set each time the power is turned on.
q
To set the effect data, push the PARAMETERS knob and select
YES
.
•“
Set OK?
flashes on the character display.
w
Push the PARAMETERS knob again and select
OK
to execute setting the data.
e
Once setting is completed,
Complete!
is displayed.
(6)
AUTO LOAD : Time for automatically loading disc. (OFF / 10 / 30 / 60* seconds)
(7)
EOM : Track end message start time. (OFF / 10* / 15 / 20 / 30 / 60 / 90 seconds)
(8)
DIGITAL OUT OUTPUT LEVEL : Select the digital out output level. (Normal* /
6 dB Down)
NOTE:
Use
6dB if the playback output is clipped when the Main and Alpha-Tracks are played
simultaneously at the same position.
(9)
FADER START MODE: Select 2-line type (Cue and Play) or 1 line type (Play and Pause).
(Play /Cue* / Play/Pause)
(10)
POWER ON PLAY : Playback starts when the power is turned on if a disc is loaded. (On / Off*)
(11)
A3/4 MODE : Select the A3 and A4 button operating modes when the power is turned on.
(Sampler* / 4H/S / Alpha-Track H/S)
(12)
SINGLE/CONTINUOUS : Select the play mode when the power is turned on. (Single* / Continuous)
(13)
ELAPSED/REMAIN: Select the time mode when the power is turned on.
(Elapsed* / Remain)
(14)
PROGRAM ALL CLEAR : Clear all program play data in the non-volatile memory.
q
To clear the program, push the PARAMETERS knob and select
YES
.
•“
Clear OK?
flashes on the character display.
w
Push the PARAMETERS knob again and select
OK
to execute clearing the program.
Prog. Clear
is displayed on the character display while data clearing.
e
Once clearing is completed,
Complete!
is displayed.
(15)
MEMO ALL CLEAR : Clear all MEMO data in the non-volatile memory.
q
To clear all MEMO data, push the PARAMETERS knob and select
YES
.
•“
Clear OK?
flashes on the character display.
w
Push the PARAMETERS knob again and select
OK
to execute clearing all MEMO data.
•“
Memo Clear
is displayed on the character display while clearing.
e
Once clearing is completed,
Complete!
is displayed.
(16)
MEMO ALL COPY :
Copy all MEMO data from the master unit of DN-S5000 (or DN-D9000, DN-2600F) to the slave unit
of DN-S5000 (or DN-D9000) when both unit are connected by the normal straight Cable. (See
diagram for the cable.)
NOTE:
Be sure CD player have no discs inside.
A straight cable used:
Using the straight cable, connect the X-EFFECT terminals between two DN-S5000 units or
between one DN-2600F and one DN-S5000 unit or between one DN-D9000 and one DN-S5000
unit.
If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F
beforehand. (For details, refer to the DN-2600F
s operating instructions.)
Set the
Copy Master
for the Preset item (14).
Then, step to the
q
below on the slave unit of DN-S5000.
Copying can be performed using the DN-S5000 and DN-D9000 in the same way as when using
two units of the DN-S5000.
Perform the copying operation as below on the slave unit of DN-S5000.
q
To start copying, push the PARAMETERS knob and select
YES
. Now
Copy OK?
messages flashes on the character display.
w
Push the PARAMETERS knob again to confirm.
Now
Start OK?
is displayed.
NOTE:
If a DN-2600F is the master unit, take the procedures below in the Preset mode of
the DN-2600F here.
In the Preset item (15), first start copying on the DN-2600F. Then, step to
e
below
on the slave unit of DN-S5000.
e
Push the PARAMETERS knob once again, and the unit starts copying when the MEMO data
are received from the master unit.
Now
Copying
is displayed.
If the master unit and the slave unit are not connected properly or the DN-2600F is not
prepared to start sending data,
Not Connect
is displayed on the character display.
r
When copying is completed correctly,
Complete!
is displayed.
•“
Copy Error
is displayed on the character display if copying was not completed correctly.
In this case, try the above procedure again.
The copied MEMO data are added to the highest number area of the slave DN-S5000 unit.
(17)
The DN-S5000
s software version is displayed. (SYSTEM / DSP / CD DRIVE)
(18)
PRESET CLEAR : Set all the preset data back to the factory defaults.
q
To clear the PRESET data, push the PARAMETERS.
Initial OK?
flashes on the character display.
w
Push the PARAMETERS knob again and select
OK
to start clear the preset data.
Preset Int
is displayed on the character display while data clearing.
e
Once clearing is completed,
Complete!
is displayed.
DN-S5000
DN-S5000 (X'EFFECT IN)
DN-2600F (X'EFFECT)
DN-D9000 (X'EFFECT)
X'EFFECT OUT
POWER
ON
OFF
DIGITAL OUT
X-EFFECT
ALPHA
IN
OUT
MAIN
L
L
LINE OUT
R
R
FADER
MAIN
MONITOR
POWER
ON
OFF
DIGITAL OUT
X-EFFECT
ALPHA
IN
OUT
MAIN
L
L
LINE OUT
R
R
FADER
MAIN
MONITOR
X-EFFECT IN jack
DN-S5000-1
DN-S5000-2
X-EFFECT OUT jack
3.5 mm stereo mini cord