Fader start mode, Set value, Processing, Index tally, Mono mode, Auto sleep mode, END MON

Page 40 highlights

ENGLISH 3. DEVICE OPERATION 11. Fader start mode (Fader Start) This feature allows you to decide how the DN-C620 behaves when the Fader Start pins are short-circuited. Set value Play Play-Pause (default) Processing Unit starts playback when the remote fader pins (9-23) are short circuited and remains playing when the pins open Unit starts playback when the remote fader pins (9-23) are short circuited and pauses playback when the pins open 12. Index tally (Index Tally) This feature allows you to select the processing of INDEX tally pin (17) of the parallel control terminal. Set value Index2 (default) Index3 Output index 2 tally signal to INDEX tally pin (17). Output index 3 tally signal to INDEX tally pin (17). Processing 13. Mono mode (Mono) This feature allows you to force playback of stereo audio into a mono signal sent out both the L and R terminals. Set value Off (default) On Processing Output L and R original signals from the output terminals. Output mixed L and R stereo signals from the output terminals. 14 Auto sleep mode (Auto Sleep) You can select the behavior that the servo functions will automatically turn off if no operation is performed for set-up time while in stop, pause or cue. When in the sleep mode, if the 2 / ; / END MON button is pressed, playback will be started from the beginning of the track in which the sleep mode was set. If the CUE button is pressed, it will standby for the beginning of the track in which the auto sleep was set. Set value Off 30sec 10min 20min 30min(default) Unit never goes into sleep mode Processing Unit will goes into sleep mode if no servo functions occur for longer than the user-designated time 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

30
3. DEVICE OPERATION
ENGLISH
11.
Fader start mode
(Fader Start)
This feature allows you to decide how the DN-C620 behaves when the Fader Start pins are short-circuited.
Set value
Processing
Play
Unit starts playback when the remote fader pins (9-23) are short circuited and remains playing when the pins open
Play-Pause (default)
Unit starts playback when the remote fader pins (9-23) are short circuited and pauses playback when the pins open
12.
Index tally
(Index Tally)
This feature allows you to select the processing of INDEX tally pin (17) of the parallel control terminal.
Set value
Processing
Index2 (default)
Output index 2 tally signal to INDEX tally pin (17).
Index3
Output index 3 tally signal to INDEX tally pin (17).
13.
Mono mode
(Mono)
This feature allows you to force playback of stereo audio into a mono signal sent out both the L and R terminals.
Set value
Processing
Off (default)
Output L and R original signals from the output terminals.
On
Output mixed L and R stereo signals from the output terminals.
14
Auto sleep mode
(Auto Sleep)
You can select the behavior that the servo functions will automatically turn off if no operation is performed for set-up time while in stop, pause or cue.
When in the sleep mode, if the
2
/
;
/ END MON
button is pressed, playback will be started from the beginning of the track in which the sleep mode was set. If the
CUE
button is pressed,
it will standby for the beginning of the track in which the auto sleep was set.
Set value
Processing
Off
Unit never goes into sleep mode
30sec
10min
20min
30min(default)
Unit will goes into sleep mode if no servo functions occur for longer than the user-designated time