Electrolux E42BS75ETT Owners Manual - Page 17

JL iI'T

Page 17 highlights

Installation Instructions THE INSTALLATION SPACE 3" _ Finished Width 74" FromFloor to Bottom 0f Electrical DIMENSIONS AND CLEARANCES "81-3/ at Re_ 25-3/8" Case Depth *Shipping height The front height may be adjusted from 83-1/2"to 84-1/2" byadjusting front and rear leveling legs a maximumof 1". *The finished cutout width must be: 41-1/2" for 42" models Depth Including Handles 26-7/8" Water and Electrical Locations The opening must be prepared with the electrical and water supply located as shown. The cutout depth must be 24" The refrigerator will project forward, beyond adjacent cabinets, depending your installation. slightly on Additional Specifications • A 120 volt, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown. Note: GFI (ground fault interrupter) is not recommended. Water line can enter the opening through the floor or rear wall. The water line installed should be 1/4" O.D. copper tubing between the cold water line and water connection location. The line should be long enough to extend to the front of the refrigerator. Installation of an easily accessible shutoff valve in the water line is required. Product Clearances These refrigerators are equipped with a 2 position door stop. The factory set 130 ° door swing can be adjusted to 90 ° if clearance to adjacent cabinets or walls is restricted. 130 ° Door Swing 90 ° Door Swing / Behind Flame x _JL i I'T "... ,/ i.Dj J Models A B C 42" 12-3/16" 16" 24" J _D4 D 4" Allow minimum clearances for Freezer door (Dimension A) and Fresh Food door (Dimension B) for a full 130 ° door swing and to allow for drawer removal. Four inch (4") minimum clearance is required when door swing is adjusted to 90 °. If the 90 ° door stop position is used, drawer access is maintained, but drawer removal is restricted. See illustrations, pages 18 and 19, to determine door swing interaction with adjacent cabinets or countertops. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Installation
Instructions
THE INSTALLATION
SPACE
_
Finished Width
3"
74"
FromFloor
to Bottom
0f Electrical
*The
finished
cutout
width
must
be:
41-1/2"
for
42"
models
Water
and
Electrical
Locations
The
opening
must
be prepared
with
the
electrical
and
water
supply
located
as shown.
The cutout
depth
must
be 24"
The
refrigerator
will
project
forward,
slightly
beyond
adjacent
cabinets,
depending
on
your
installation.
Additional
Specifications
A 120 volt,
60Hz,
15 or
20 amp
power
supply
is required.
An
individual
properly
grounded
branch
circuit
or circuit
breaker
is recommended.
Install
a properly
grounded
3-prong
electrical
receptacle
recessed
into
the
back
wall.
Electrical
must
be located
on
rear
wall
as shown.
Note:
GFI (ground
fault
interrupter)
is not
recommended.
Water
line
can enter
the opening
through
the
floor
or rear
wall.
The
water
line
installed
should
be 1/4"
O.D.
copper
tubing
between
the
cold
water
line
and
water
connection
location.
The
line
should
be
long
enough
to extend
to the
front
of the
refrigerator.
Installation
of an easily
accessible
shutoff
valve
in the
water
line
is
required.
DIMENSIONS
AND
CLEARANCES
25-3/8" Case Depth
"81-3/
at Re_
*Shipping height
The front height
may be adjusted
from 83-1/2"to 84-1/2"
byadjusting front and
rear leveling legs a
maximumof 1".
Depth Including
Handles 26-7/8"
Product
Clearances
These
refrigerators
are equipped
with
a2
position
door
stop.
The
factory
set
130 ° door
swing
can
be adjusted
to
90 ° if clearance
to
adjacent
cabinets
or
walls
is restricted.
130 ° Door
Swing
90 ° Door
Swing
/ Behind
Flame
x
_JL iI'T
"...
,/
i.Dj
J
J
_D4
Models
A
B
C
D
42"
12-3/16"
16"
24"
4"
Allow
minimum
clearances
for
Freezer
door
(Dimension
A) and
Fresh
Food
door
(Dimension
B) for
a full
130 ° door
swing
and
to
allow
for
drawer
removal.
Four
inch
(4")
minimum
clearance
is required
when
door
swing
is adjusted
to
90 °. If the
90 °
door
stop
position
is used,
drawer
access
is
maintained,
but
drawer
removal
is restricted.
See
illustrations,
pages
18 and
19, to
determine
door
swing
interaction
with
adjacent
cabinets
or countertops.
17