Fisher and Paykel OR36SCG6R1 Installation Guide - Page 23

Injectors table, GAS GAS MODELS ONLY, Replacing the cooktop burner injectors

Page 23 highlights

GAS CONVERSION Injectors table BURNERS Semi-rapid (SR) LP/Propane Gas Natural Gas Triple ring LP/Propane Gas Natural Gas Dual (D) Inner crown Full burner NOMINAL POWER BTU/HR 7600 8000 12000 14000 28001 180002 REDUCED POWER BTU/HR LP/PROPANE 11" (279.4mm) W.C.P. Ø INJECTOR [1/100 MM] NATURAL GAS 4" (101.6MM) W.C.P. Ø INJECTOR [1/100 MM] 1800 78 n/a 1800 n/a 136 6300 97 n/a 6300 n/a 180 11001 65002 473 79 (x2)4 803 135 (x2)4 GAS GAS MODELS ONLY Oven burner Broil burner 17000 13000 3200 n/a 1 Power calculated with inner and outer crown operating 2 Power calculated with inner and outer crown operating 3 Inner crown injector 4 Outer crown injector 120 208 105 184 Replacing the cooktop burner injectors z Remove the pan supports, the burner caps and the flame spreaders. z Using a wrench substitute the nozzle injectors with those most suitable for the kind of gas for which it is to be used. z Refit the flame spreaders, the burner caps and the pan supports. The burners are designed so that no regulation of the primary air is required. Inner crown injector Inner crown injector Inner crown injector Semi-rapid burner Outer crown injector Dual burner 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

23
Injectors table
BURNERS
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11" (279.4mm)
W.C.P.
NATURAL GAS
4" (101.6MM)
W.C.P.
BTU/HR
BTU/HR
Ø INJECTOR
[1/100 MM]
Ø INJECTOR
[1/100 MM]
Semi-rapid (SR)
LP/Propane Gas
7600
1800
78
n/a
Natural Gas
8000
1800
n/a
136
Triple ring
LP/Propane Gas
12000
6300
97
n/a
Natural Gas
14000
6300
n/a
180
Dual (D)
Inner crown
2800
1
1100
1
47
3
80
3
Full burner
18000
2
6500
2
79 (x2)
4
135 (x2)
4
GAS GAS MODELS ONLY
Oven burner
17000
3200
120
208
Broil burner
13000
n/a
105
184
1
±Power calculated with inner and outer crown operating
2
±Power calculated with inner and outer crown operating
3
±Inner crown injector
4
±Outer crown injector
Replacing the cooktop burner injectors
Remove the pan supports, the burner caps and the flame spreaders.
Using a wrench substitute the nozzle injectors with those most suitable for the kind of
gas for which it is to be used.
Refit the flame spreaders, the burner caps and the pan supports.
The burners are designed so that no regulation of the primary air is required.
GAS CONVERSION
Semi-rapid burner
Dual burner
Outer crown injector
Inner crown
injector
Inner crown
injector
Inner crown
injector