Fisher and Paykel OR36SCG6R1 Installation Guide - Page 24
Adjusting the cooktop burner minimums
View all Fisher and Paykel OR36SCG6R1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
GAS CONVERSION Adjusting the cooktop burner minimums When switching from one type of gas to another, the minimum flow rate must also be correct: z The flame should not go out even when passing suddenly from maximum to minimum flame. To regulate the flame follow these instructions: Semi-rapid burner (A) z Light the burner z Set the gas valve to position (minimum rate) z Remove the dial. z With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct. Inside crown of DUAL burner (B) z Light the dual burner z Set the gas valve to position (minimum rate of inner crown) z Remove the dial z With a thin screwdriver, turn the regulation screw until adjustment is correct. z The screw is accessible via a hole in the microswitch. Outside crown of DUAL burner (C) z Light the dual burner z Set the gas valve to position (minimum rate of outer crown and maximum rate of inner crown). z Remove the dial z With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct. For LP/PROPANE gas, tighten the adjustmentacrews completely. A Regulation screw (triple ring and semi-rapid burner) B Regulation screw (inner crown of dual burner) C Regulation screw (outer crown of dual burner) Regulation screws A Regulation screws C B Regulation screws 24