Fujitsu MAN3735MC Manual/User Guide - Page 73

See Physical Requirements, in SCSI, A3B-12D-2C

Page 73 highlights

Table 4.2 Recommended components for connection Applicable model Name Par number (Size) Reference Manufacturer (Figures 4.25 and 4.30) SCSI cable (CN1) Cable socket (closedend type) DHJ-PAC68-2AN DDK Signal cable UL20528-FRX-68P0.635 Fujikura S1 Cable socket housing 1-480424-0 Power supply cable (CN1) Contact 170148-1 Tyco Electronics AMP Tyco Electronics S2 AMP Cable (AWG18 to 24) MP External Cable socket housing A3B-12D-2C HIROSE ELECTRIC operator panel (CN1) Contact A3B-2630SCC HIROSE ELECTRIC S3 Cable (AWG26 to 36) External Cable socket housing FCN-723J016/2M FUJITSU TAKAMIZAWA operator panel (CN2) Contact FCN-723J-G/AM FUJITSU TAKAMIZAWA S4 Cable (AWG28) SCSI MC connector Connector (CN1) 71780-003 FCI (1) SCSI cable See Section 1.3, "Physical Requirements", and Section 1.4, "Electrical Requirements", in SCSI Physical Interface Specifications. (2) Power cable IDDs must be star-connected to the DC power supply (one to one connection) to reduce the influence of load variations. (3) DC ground The DC ground cable must always be connected to the IDD because no fasten terminal dedicated to SG is provided with the IDD. Therefore, when SG and FG are connected in the system, it is necessary to connect SG and FG at the power supply or to connect SG of the power supply to FG of the system. (4) External operator panel (MP model only) The external operator panel is installed only when required for the system. When connection is not required, leave open the following pins in the external operator panel connector of the IDD : Pins 21, 22 and pins 01 through 08 in CN2 and pins A1 through A12 in CN1. C141-E128-01EN 4 - 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145

C141-E128-01EN
4 - 21
Table 4.2
Recommended components for connection
Applicable
model
Name
Par number
(Size)
Manufacturer
Reference
(Figures 4.25
and 4.30)
Cable socket (closed-
end type)
DHJ-PAC68-2AN
DDK
SCSI cable
(CN1)
Signal cable
UL20528-FRX-68-
P0.635
Fujikura
S1
Cable socket housing
1-480424-0
Tyco Electronics
AMP
Contact
170148-1
Tyco Electronics
AMP
Power supply
cable (CN1)
Cable
(AWG18 to 24)
S2
Cable socket housing
A3B-12D-2C
HIROSE
ELECTRIC
Contact
A3B-2630SCC
HIROSE
ELECTRIC
External
operator
panel (CN1)
Cable
(AWG26 to 36)
S3
Cable socket housing
FCN-723J016/2M
FUJITSU
TAKAMIZAWA
Contact
FCN-723J-G/AM
FUJITSU
TAKAMIZAWA
MP
External
operator
panel (CN2)
Cable
(AWG28)
S4
MC
SCSI
connector
(CN1)
Connector
71780-003
FCI
(1)
SCSI cable
See Section 1.3, “Physical Requirements”, and Section 1.4, “Electrical Requirements”, in SCSI
Physical Interface Specifications.
(2)
Power cable
IDDs must be star-connected to the DC power supply (one to one connection) to reduce the
influence of load variations.
(3)
DC ground
The DC ground cable must always be connected to the IDD because no fasten terminal dedicated
to SG is provided with the IDD.
Therefore, when SG and FG are connected in the system, it is
necessary to connect SG and FG at the power supply or to connect SG of the power supply to FG
of the system.
(4)
External operator panel (MP model only)
The external operator panel is installed only when required for the system.
When connection is
not required, leave open the following pins in the external operator panel connector of the IDD :
Pins 21, 22 and pins 01 through 08 in CN2 and pins A1 through A12 in CN1.