GE NX-148E User Manual - Page 27

Appendix A - Event Log - user s manual

Page 27 highlights

APPENDIX A - EVENT LOG NOTE: Your system may not have all of the features listed in this table. DISPLAY TXlobat ZN Lost Duress Man Fire Aux 2 Panic KP Tamper BoxTamp AC Fail OverCur Srn Tamp Tel Flt Exp Trb Log Full Open Close Exit Err Rec Close Autotest Start Prog End Prog Start Dnld End Dnld NX148E-CF DESCRIPTION Transmitter Low Battery The transmitter has a low battery. Zone Lost A wireless or multiplexed zone device is not reporting to the control. Duress The control has been armed or disarmed with a Duress code. Manual Fire Keypad "Fire" has been activated. Auxiliary 2 Keypad "Medical" has been activated. Panic Keypad "Panic" has been activated. Keypad Tamper The keypad tamper has been activated. Box Tamper The box tamper circuit has been activated. AC Fail AC failure has been detected. Over Current A short circuit of a power supply has occurred. Siren Tamper A siren or speaker tamper has been detected. Telephone Fault A telephone fault or tamper has been detected. Expansion Trouble An expansion device or keypad is not reporting to the control. Log Full The event log is full. Old events will be pushed out as new ones enter the log. Open Reports user number, date, time and partition of opening. Close Reports user number, date, time and partition of closing. Exit Error Entry/Exit zone was faulted at the instant the exit delay expired. Recent Close An alarm occurred within 5 minutes after the control was armed. Auto Test Sending a communicator test at a specified interval. Start Local programming is started. Programming End Local programming is ended. Programming Start Download Download session is started. End Download Download session is ended. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

NX148E-CF
25
APPENDIX A - EVENT LOG
NOTE: Your system may not have all of the features listed in this table.
DISPLAY
DESCRIPTION
TXlobat
Transmitter
Low Battery
The transmitter has a low battery.
ZN Lost
Zone Lost
A wireless or multiplexed zone device is not
reporting to the control.
Duress
Duress
The control has been armed or disarmed with a
Duress code.
Man Fire
Manual Fire
Keypad “Fire” has been activated.
Aux 2
Auxiliary 2
Keypad “Medical” has been activated.
Panic
Panic
Keypad “Panic” has been activated.
KP Tamper
Keypad
Tamper
The keypad tamper has been activated.
BoxTamp
Box Tamper
The box tamper circuit has been activated.
AC Fail
AC Fail
AC failure has been detected.
OverCur
Over Current
A short circuit of a power supply has occurred.
Srn Tamp
Siren Tamper
A siren or speaker tamper has been detected.
Tel Flt
Telephone
Fault
A telephone fault or tamper has been detected.
Exp Trb
Expansion
Trouble
An expansion device or keypad is not reporting
to the control.
Log Full
Log Full
The event log is full. Old events will be pushed
out as new ones enter the log.
Open
Open
Reports user number, date, time and partition of
opening.
Close
Close
Reports user number, date, time and partition of
closing.
Exit Err
Exit Error
Entry/Exit zone was faulted at the instant the
exit delay expired.
Rec Close
Recent Close
An alarm occurred within 5 minutes after the
control was armed.
Autotest
Auto Test
Sending a communicator test at a specified
interval.
Start Prog
Start
Programming
Local programming is started.
End Prog
End
Programming
Local programming is ended.
Start Dnld
Start Download
Download session is started.
End Dnld
End Download
Download session is ended.