Set the Power Thermostat Select switch to either Pool or Spa.

Page 12 highlights

Hayward Heaters Refer to the instructions in the heater manual for "2-wire Remote Thermostat" operation under "Remote Control Connections" and the diagram below: 1. Turn off power to heater. 2. Wire ECOMMAND 4 to terminals 1 & 2 (see diagram). 3. Leave jumper attached to terminals 4 & 5. 4. Move "BYPASS" dipswitch on heater circuit board to "ON" position (up). 5. Turn heater power back on. 6. Switch heater to either "Pool" or "Spa" (it doesn't make any difference which is selected, the ECOMMAND 4 will take control). 7. Heater display should be "bO" (for "bypass On). 8. Heater will fire whenever ECOMMAND 4 requests (when ECOMMAND 4 "Heater" LED is il- luminated). ºC ON ºF OFF Dipswitch located on heater circuit board PK W R BK R Pool/Spa Air Solar Heater Terminal block located at electrical junction box Do not remove jumper Pentair/Purex/MiniMax 1. Turn power off to heater. 2. Remove factory installed jumper from the "Ext Switch" connector. 3. Wire the ECOMMAND 4 to the "Ext Switch" connector as shown below. 4. The wires to the ECOMMAND 4 must be separated from any line voltage wires. Failure to follow these instructions may cause erratic operation of the heater. 5. Set the Power (Thermostat Select) switch to either "Pool" or "Spa". 6. Set the "Pool" and "Spa" thermostats to their maximum settings. Remove Factory Jumper Ext. Switch MINIMAX Pool/Spa Air Solar Heater 11 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
Hayward Heaters
Refer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under
“Remote Control Connections” and the diagram below:
1.
Turn off power to heater.
2.
Wire ECOMMAND 4 to terminals 1 & 2 (see diagram).
3.
Leave jumper attached to terminals 4 & 5.
4.
Move “BYPASS” dipswitch on heater circuit board to “ON” position (up).
5.
Turn heater power back on.
6.
Switch heater to either “Pool” or “Spa” (it doesn’t make any difference which is selected, the
ECOMMAND 4 will take control).
7.
Heater display should be “bO” (for “bypass On).
8.
Heater will fire whenever ECOMMAND 4 requests (when ECOMMAND 4 “Heater” LED is il-
luminated).
Pentair/Purex/MiniMax
1.
Turn power off to heater.
2.
Remove factory installed jumper from the “Ext Switch” connector.
3.
Wire the ECOMMAND 4 to the “Ext Switch” connector as shown below.
4.
The wires to the ECOMMAND 4 must be separated from any line voltage wires.
Failure to
follow these instructions may cause erratic operation of the heater.
5.
Set the Power (Thermostat Select) switch to either “Pool” or “Spa”.
6.
Set the “Pool” and “Spa” thermostats to their maximum settings.
Air
Solar
Pool/Spa
Heater
Do not remove jumper
Terminal block located at
electrical junction box
Dipswitch located on heater