Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Installation-Manual-092419AR - Page 17

Configuration

Page 17 highlights

Configuration After plumbing and wiring are complete, the ECOMMAND 4 MUST BE CONFIGURED before attempting to operate. Configuration information is entered at the keypad and "tells" the ECOMMAND 4 what equipment is connected and how each should be controlled. Accessing the Configuration Menus Configuring the ECOMMAND 4 requires that you navigate through the Configuration Menu and input various information. For more detailed information about using the ECOMMAND 4 menu system, refer to the Operation Manual. To access the Configuration Menu Configuration Menu-Locked Press repeatedly until "Configuration Menu" is displayed Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock Configuration Menu-Unlocked Move to configuration menu items NOTE: The configuration menu automatically "locks" after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a "call back" to fix the configuration. Configuration Menu Items Each item needs to be programmed and may contain additional sub-menu items. Refer to the fol- lowing pages for information on programming. Chlor. Config. + to view/change Push to access Chlorinator option Move to next configuration menu Ext. Chlorinator Enabled Toggle between External Chlorinator Enabled and Disabled (default) Move to next menu item Display Salt Toggle between Display Salt (default) and Minerals Move to previous/next configuration menu Chlorinator If the optional external chlorinator is enabled (requires the use of a Hayward Aqua Rite or Hayward Swimpure chlorinator), the ECOMMAND 4 will automatically chlorinate both the pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If disabled (default), all displays relating to the chlorinator will be suppressed. When the chlorinator is enabled, the ECOMMAND 4 will automatically detect and control any Aqua Rite/Swimpure(s) that is installed in the system. Display Allows for the display of salt (default) or mineral values. 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
16
Configuration
After plumbing and wiring are complete, the ECOMMAND 4 MUST BE CONFIGURED before
attempting to operate.
Configuration information is entered at the keypad and “tells” the ECOM-
MAND 4 what equipment is connected and how each should be controlled.
Accessing the Configuration Menus
Configuring the ECOMMAND 4 requires that you navigate through the Configuration Menu and
input various information.
For more detailed information about using the ECOMMAND 4 menu
system, refer to the Operation Manual.
To access the Configuration Menu
NOTE:
The configuration menu automatically “locks” after 2 minutes of no buttons
being pressed to prevent unauthorized people from changing the control logic inad-
vertently and possibly damaging the pool equipment or causing a “call back” to fix the
configuration.
Configuration Menu Items
Each item needs to be programmed and may contain additional sub-menu items.
Refer to the fol-
lowing pages for information on programming.
Chlorinator
If the optional external chlorinator is enabled (requires the use of a Hayward Aqua Rite
or Hayward Swimpure chlorinator), the ECOMMAND 4 will automatically chlorinate both
the pool and spa according to the desired output setting (see Settings Menu in the
Operation manual).
If disabled (default), all displays relating to the chlorinator will be
suppressed.
When the chlorinator is enabled, the ECOMMAND 4 will automatically detect and
control any Aqua Rite/Swimpure(s) that is installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Configuration
Menu-Unlocked
Configuration
Menu-Locked
Press repeatedly until “Configuration Menu” is displayed
Move to configuration menu items
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Move to next menu item
Ext. Chlorinator
Enabled
Display
Salt
Chlor. Config.
+ to view/change
Toggle between Display Salt (default) and Minerals
Toggle between External Chlorinator Enabled and Disabled (default)
Move to previous/next configuration menu
Move to next configuration menu
Push to access Chlorinator option