Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Installation-Manual-092419AR - Page 16

ECOMMAND 4, Aqua Rite, Swimpure

Page 16 highlights

Hayward Aqua Rite or Hayward Swimpure Chlorinator The ECOMMAND 4 can control one or more Hayward Aqua Rite or Hayward Swimpure chlorinators when additional sanitizing capacity is required. A 4 wire connection is used to communicate to the Aqua Rite/Swimpure and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Refer to the wiring diagrams below for proper wiring connection to the Aqua Rite/ Swimpure. NOTE: There must be only 1 "primary" unit. All other Aqua Rite/Swimpure units must be configured as "secondary". Jumper Installed For Primary (Factory Default) ECOMMAND 4 Aqua Rite or Swimpure (Primary) 4 GREEN 3 YELLOW 2 BLACK 1 RED Jumper Removed For Secondary(s) Aqua Rite or Swimpure (Secondary) Additional Aqua Rite/Swimpure(s) (if required) NOTE: Primary/Secondary jumper is located underneath small circuit board. GRN 4 ECOMMAND 4 YEL BLK 3 2 RED 1 green yellow black red 4 GRN Aqua Rite 3 YEL or 2 BLK Swimpure 1 RED 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
15
Hayward Aqua Rite or Hayward Swimpure Chlorinator
The ECOMMAND 4 can control one or more Hayward Aqua Rite or Hayward Swimpure chlorinators
when additional sanitizing capacity is required.
A 4 wire connection is used to communicate to
the Aqua Rite/Swimpure and can be wired up to 500’ apart.
Any outdoor rated 4 conductor cable
can be used.
Refer to the wiring diagrams below for proper wiring connection to the Aqua Rite/
Swimpure. NOTE: There must be only 1 “primary” unit.
All other Aqua Rite/Swimpure units must be
configured as “secondary”.
ECOMMAND 4
Aqua Rite
or
Swimpure
(Primary)
Aqua Rite
(Secondary)
or
Swimpure
Additional
Aqua Rite/Swimpure(s)
(if required)
Jumper Removed
For Secondary(s)
Jumper Installed
For Primary
(Factory Default)
1
2
3
4
GREEN
YELLOW
BLACK
RED
NOTE: Primary/Secondary jumper is located underneath small circuit board.
4
4
3
3
2
2
1
1
GRN
GRN
BLK
BLK
YEL
YEL
RED
RED
ECOMMAND 4
Aqua Rite
or
Swimpure
green
yellow
black
red