Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Installation-Manual-092419AR - Page 20

Freeze Protection, Freeze Protection Speed, Freeze Protection Temperature, Heater1, Heater Cooldown

Page 20 highlights

Freeze Protection Freeze protection is used to protect the pool and plumbed equipment against freeze damage. If freeze protection is enabled and the AIR temperature falls below the freeze threshold (see below), the ECOMMAND 4 will turn on the filter pump to circulate the water. If "Pool and Spa" is selected in the Pool/Spa sub-menu (see page 17), the valves will also alternate between the pool and spa every 30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only reason the pump is running. Freeze Protection Speed This menu only appears if freeze protection is enabled and the pump is configured for 2-speed or variable speed pump operation. This is the speed that the pump will run at during freeze protection operation. Select high (default) or low speed operation. Freeze Protection Temperature Select the temperature to be used for freeze protection. Temperature is adjustable from 33ºF - 42ºF (1ºC - 6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled. Heater1 Config. + to view/change Push to access heater options Move to previous/next configuration menu Heater1 Toggle between Enabled and Disabled (default) Heater 1 Disable Move to next menu item or previous/next configuration menu if "Heater1" is enabled Heater1 Cooldown Disabled Toggle between Enabled and Disabled (default) Heater 1 Cooldown Move to next menu item if "Heater1" is enabled Heater1 Extend Toggle between Enabled and Disabled (default) Heater 1 Extend Disabled Move to previous/next configuration menu if "Heater1" is enabled and 1-speed filter pump is not selected Allow Low Speed Toggle between Enabled and Disabled (default) Disabled Move to next menu item or previous/next configuration menu Heater1 If the heater is "Enabled", the heater relay will turn on when the water temperature is less than the desired temperature setting and the filter pump is running. The desired temperature is in the "Settings Menu". If applicable, the homeowner will be prompted to enter separate "pool" and "spa" settings. Depending on the position of the pool/spa suction valve, the proper temperature setting will be used. Heater Cooldown This feature ensures that the heater cools down before water circulation is stopped. When enabled, the ECOMMAND 4 will continue to run the filter pump for 5 minutes after the heater turns off. During this period the filter pump LED will flash and also a "Heater Cooldown, X:XX remaining" message will scroll on the display. When the filter pump is running and the heater is on: Pressing the "Filter" button once will cause the heater to turn off, but the filter pump will continue to run for heater cooldown (filter LED flashing and message on display). Pushing the filter button a second time will override the heater cooldown operation and turn the filter pump off. 19 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
19
Freeze Protection
Freeze protection is used to protect the pool and plumbed equipment against freeze
damage.
If freeze protection is enabled and the AIR temperature falls below the freeze
threshold (see below), the ECOMMAND 4 will turn on the filter pump to circulate the
water. If “Pool and Spa” is selected in the Pool/Spa sub-menu (see page 17), the valves
will also alternate between the pool and spa every 30 minutes and the filter pump will
turn off while the valves are turning.
The chlorinator will not operate if freeze protection
is the only reason the pump is running.
Freeze Protection Speed
This menu only appears if freeze protection is enabled and the pump is configured for
2-speed or variable speed pump operation. This is the speed that the pump will run at
during freeze protection operation. Select high (default) or low speed operation.
Freeze Protection Temperature
Select the temperature to be used for freeze protection.
Temperature is adjustable
from 33ºF
-
42ºF (1ºC - 6ºC).
38ºF (3ºC) is default. This threshold will be used for all
outputs that have freeze protection enabled.
Heater1
If the heater is “Enabled”, the heater relay will turn on when the water temperature is
less than the desired temperature setting and the filter pump is running.
The desired
temperature is in the “Settings Menu”.
If applicable, the homeowner will be prompted
to enter separate “pool” and “spa” settings.
Depending on the position of the pool/spa
suction valve, the proper temperature setting will be used.
Heater Cooldown
This feature ensures that the heater cools down before water circulation is stopped.
When enabled, the ECOMMAND 4 will continue to run the filter pump for 5 minutes
after the heater turns off.
During this period the filter pump LED will flash and also a
“Heater Cooldown, X:XX remaining” message will scroll on the display.
When the filter pump is running and the heater is on:
Pressing the “Filter” button
once will cause the heater to turn off, but the filter pump will continue to run for heater
cooldown (filter LED flashing and message on display).
Pushing the filter button a
second time will override the heater cooldown operation and turn the filter pump off.
Heater1 Config.
+ to view/change
Heater1
Disable
Heater1 Cooldown
Disabled
Heater1 Extend
Disabled
Push to access heater options
Toggle between Enabled and Disabled (default) Heater 1
Toggle between Enabled and Disabled (default) Heater 1 Cooldown
Toggle between Enabled and Disabled (default) Heater 1 Extend
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Heater1” is enabled
if “Heater1” is enabled
Allow Low Speed
Disabled
Toggle between Enabled and Disabled (default)
Move to next menu item or previous/next configuration menu
if “Heater1” is enabled and
1-speed filter pump is not selected